TB-9102
Page 17 of 18
© 2020 DESCO INDUSTRIES INC
Employee Owned
SCS
- 926 JR Industrial Drive, Sanford, NC 27332
East: (919) 718-0000 | West: (909) 627-9634 • Website:
Calibration
Frequency of recalibration should be based on the
critical nature of those ESD sensitive items handled and
the risk of failure for the ESD protective equipment and
materials. In general, SCS recommends that calibration
be performed annually.
Use the SCS CTE701
Workstation Monitor Checker to
perform periodic verification (once every 6-12 months)
of the WS Aware Monitor. The Workstation Monitor
Checker can be used to check the test limits of the WS
Aware Monitor without removing it from the factory floor.
See
Specifications
WS Aware Monitor
Power
Power Adapter
100-240VAC
50-60 Hz
Output: 7.5 VDC @ 1.5 A
Output Plug Polarization: Center
Positive
Output Plug: 5.5 mm O.D. x 2.1
mm I.D. x 9.5 mm L
Operator
Wrist Strap
Dual-Wire
Amount Monitored
(Operator)
2
Amount Non-
Monitored (Visitor)
2
Resistance Limit
10 megohms (default)
Programmable
Resistance Range
2 to 35 megohms
Body Voltage Limit ±2.5 VDC (default)
Programmable
Voltage Range
0 to ±5.0 VDC
Test Voltage
50 mV @ open circuit,
peak-to-peak
Worksurface Mat
Amount Monitored 2
Resistance Limit
100 megohms (default)
Programmable
Resistance Range
100 megohms to 1 gigohm
Metal Tool
Amount Monitored 2
Impedance Limit
10 ohms (default)
Programmable
Impedance Range
1 to 20 ohms
EMI Voltage Limit 223 mV @ 1.8 MHz
Programmable
EMI Range
1 to 1,000 mV
Connectivity
Input
Mini-DIN for operator remotes;
25-28 AWG wire terminal block for
worksurface mats and metal tools
Outputs
RJ45 connector Ethernet output;
Molex #53261-0371 connector for
relay output
Figure 15. SCS CTE701 Workstation Monitor Checker