TB-9071
Page 4 of
6
© 2016 DESCO INDUSTRIES, INC.
Employee Owned
INSTALLING THE
770031
COMBO TESTER WITH
STAND AND FOOT PLATE
1. Position the pedestal on top of the foot plate with
the mounting bracket sloping toward the operator.
Secure the pedestal to the foot plate using the 3
included button head screws and allen wrench.
Figure 7. Securing the pedestal to the foot plate
2. Install the 9V alkaline battery into the Combo
Tester.
3.
Mount the Combo Tester onto the pedestal’s
mounting bracket and flat head screw, and screw
down to secure it into place.
4.
Insert the 5" long foot plate cord’s banana plug into
the Combo Tester’s f
oot plate jack.
5.
Attach the foot plate cord’s ring terminal to the flat
head screw located at the back of the pedestal’s
mounting bracket, and tighten the knurled nut to
secure.
Figure 9. Completed Combo Tester with Stand and
Foot Plate assembly
Operation
WRIST STRAP TEST
1. While wearing a wrist strap, plug the wrist cord
into the wrist strap jack located on the face of the
Combo Tester.
2. Toggle the rocker switch to the right toward WRIST
STRAP.
3. Push down and hold the test switch until the test
results are displayed. Ensure that your finger also
makes contact with the metal ring around the
pushbutton when performing a test.
DO NOT touch any other metal while performing
your test as this will affect your results.
Figure 8. Installing the Combo Tester to the pedestal
6. Cover the knurled nut and flat head screw with
included insulative vinyl cap.
7. Install the included poster at eye level nearby the
test station.
Figure 10. Performing a wrist strap test
SCS
- 926 JR Industrial Drive, Sanford, NC 27332
East: (919) 718-0000 | West: (909) 627-
9634 • Website:
StaticControl.com