![Screen Technics INTERFIT FVI Series Instructions Manual Download Page 10](http://html1.mh-extra.com/html/screen-technics/interfit-fvi-series/interfit-fvi-series_instructions-manual_1219705010.webp)
10
IN
AU
STRAL
IA
PR
OU
DLY BUILT
19. AMX Device Discovery
•
This feature allows the IP CONNECT module to be identified by AMX AV Control Systems.
When polled the IP CONNECT module responds with a Beacon message which contains
device specific information. (Eg Make, Model, Version) With this information the AMX
system is able to then configure itself with the correct protocol to be able to control the IP
Connect Module.
•
The protocol works for any of the Serial ports, and over TCP/IP.
•
The AMX “Device Discovery White Paper.Doc” defines, The Dynamic Device Discovery
Protocol - the connection methods and data interactions required to dynamically connect
a third party device to a NetLinx Master via either serial or IP connectivity.
•
AMX Discovery is enabled using Register 80 or via internal web browser
Continued Over.../
20. FACTORY RESET SWITCH
•
Single long press for 5 seconds approximately
- Factory Default Mode selected.
- LED double flashes.
- Pressing button again exits mode.
- Power cycle off / on for 10 seconds or
receiving an IR command exits this mode.
•
Puts module into Static IP Mode
- Default IP address is 192.168.1.253
- Module can be accessed via web browser
•
Single short press for 3 seconds approximately
- Screen Rattle command.
- 3 seconds down 1 second up.
- LED single flashes while in this function.
- Pressing button again stops screen.
- Function is exited when screen operation finished or another screen operate
command is acted on.
e.
Triple short press for 2 seconds approximately per button press
Lifter Down command. Screen travels to down limit.
LED single flashes while in this function.
Pressing button again stops screen.
Function also exited when screen operation finished or another
screen operate command is acted on
Setting Up Lifter
21. Initial Set up
•
After installing projector lift you will need to reset encoder
•
Apply power to Motor Controller
•
Send the lifter down via the IR remote control for 5 seconds, by pressing Down button on IR
remote control
•
Stop lifter by pressing stop button on IR remote
•
Send the lifter to top position by pressing Up button on IR remote control
22. SETTING THE SERVICE POSITION (BOTTOM)
•
Send the lifter to service position
•
Using the IR remote control using Group One buttons push buttons rapidly in this sequence
•
Stop – Stop – Stop – Down
•
Lifter will now move to bottom limit
•
If this position requires adjustment, this is done via the physical limits on the motor
•
White Limit adjusts Bottom Limit
•
Using the supplied limit adjusting tool
•
Clockwise rotation increases rotation of motor, moves the lifter further down
•
Anti clockwise rotation reduces rotation of motor
•
Can I adjust the switch while the lifter is sitting on the limit - ie fully up or down?
•
Clockwise adjustment? – YES. But it is better to back the lifter away from the limit and then
adjust
•
Double short press for 2 seconds approximately per button press
- Screen Up command. Screen travels to up limit.
- LED single flashes while in this function. Pressing button again stops screen.
- Function is exited when screen travels to up position or another screen operate
command is sent.
•
Triple short press for 2 seconds approximately per button press
- Screen Down command. Screen travels to down limit.
- LED single flashes while in this function.
- Pressing button again stops screen.
- Function also exited when screen operation finished or another screen operate
command is acted on.
INSTRUCTIONS -
INTERFIT