Service manual - X10
29
Troubleshooting
Problem
Cause
Solution
The ON-OFF light flashes 9
times
'BUS low' error: cable
breakage in (one of the DX
BUS cables) or short circuit
in the DX BUS system
(entrance to the modules)
Check all cables and
module and replace them if
needed.
The ON-OFF light flashes
10 times
'BUS high' error: usually a
communication error is
caused by one of the DX
BUS cables or DX modules
(entrance to the modules)
Check all cables and
module and replace them if
needed.
If the fault signal is still
present after this, contact
the Service Department of
Scout Mobility BV.
The ON-OFF light flashes
11 times
'STALL' overload error: a
motor continuously
demands too much power.
Check the drive units.
Note:
This error is often
caused by taking obstacles
that are too high, or by
driving against walls, and
door frames etc. This error
may also be caused by a
difficult turn from a standing
position. Check the weight
distribution of the
wheelchair.
The ON-OFF light flashes
11 times
System does not 'fit'.
System modules are not
compatible.
Program the entire drive
system for the relevant
wheelchair with the aid of
the DX-Wizard program on
the PC.
Always confirm the
programming by switching
the wheelchair on and off.
Summary of Contents for X10
Page 1: ...Service Manual X10 V1 0 from March 1st 2017 ...
Page 38: ...38 Service manual X10 Cable and module schemes 7 4 R Net controls ...
Page 39: ...Service manual X10 39 Cable and module schemes ...
Page 40: ...40 Service manual X10 Cable and module schemes ...
Page 41: ...Service manual X10 41 Cable and module schemes 8 Version history Version Release date Changes ...
Page 42: ...Appendices 42 Service manual X10 9 Appendices ...
Page 43: ...Parts X10 V1 0 from 01 03 2017 ...
Page 45: ...3 ...
Page 46: ...4 ...
Page 48: ...TABLE OF CONTENTS X10 EN NP 6 ...
Page 79: ......
Page 80: ......