Scott PRO-PAK User Instructions Download Page 9

PRO-PAK 

6

 

The DV has a supplementary flow device 

(bypass), that the wearer can open using 

the bypass knob. 
When  the  bypass  is  used,  the 

unregulated  flow  of  air  through  the  DV 

reduces cylinder duration. 
The DV is connected to the facemask by 

a  Quick-Fit  (QF)  bayonet  fitting  with  a 

spring-loaded  locking  catch  to  prevent 

accidental disconnection. 

2.8  OPTIONAL 

ATTACHMENTS 

The available options are: 

 

Decontamination 

attachment 

(DCC) 

facilitates 

airline 

connection  into  a  gas  tight 

chemical suit, permitting the wearer 

to  breathe  from  an  airline  during 

extended 

decontamination 

procedures. 

 

Rescue  mask  attachment  (RSM)  - 

permits  the  wearer  to  supply  a 

rescue  mask  or  an  air  powered 

resuscitator  from  own  cylinder  air. 

This  reduces  the  duration  of  the 

cylinder supply. 

 

Airline  attachment  (AL)  -  permits 

Pro-Pak

 to be used with an airline. 

The  cylinder  provides  emergency 

backup. 

Note:

 

Air  for  use  with  airline  must  conform  to 

Breathable Air as detailed in 

Section 1

2.9  FACEMASKS 

Pro-Pak 

is  approved  for  use  with:   

Vision  3

PanaSeal

PanaVisor

  and 

Pro-Mask PP

 full facemasks, all of which 

conform to EN 136, Class 3. 
All  are  available  with  five  point,  fully 

adjustable  web  or  net  head-harnesses 

and neckstraps. 
An  inner  mask  minimises  CO

2

  dead 

space  and  visor  misting.  A  speech 

diaphragm is fitted. 

PanaSeal 

is  suitable  for

 

medium  and 

smaller face sizes.

 PanaVisor 

is suitable 

for medium to larger face sizes. 

Vision 3 

is available in three sizes, small, 

medium  and  medium/large  which  cover 

most  face  sizes. 

Pro-Mask  PP

  is 

available in two sizes, small/medium and 

medium/large. 

Vision  3

  is  moulded  in  grey  silicone, 

while 

PanaSeal 

and 

PanaVisor

 are non-

dermatitic,  black  neoprene  or  blue 

silicone. 

Pro-Mask  PP

  is  moulded  in 

hypo-allergenic,  black 

Procomp

TM

  with  a 

soft silicone inner mask. 
The  polycarbonate  visors  conform  to  EN 

166, Grade B for impact resistance. 
Versions  of 

PanaSeal

PanaVisor

  and 

Vision 3

 masks are available for use with 

the 

Gallet  F1

TM

  helmet  and  the 

Rosenbauer Heros

TM

 helmet. 

 

Vision 3 Facemask with Web Harness 

 

PanaSeal/PanaVisor Facemask with 

Net Harness

Summary of Contents for PRO-PAK

Page 1: ...PRO PAK Self contained Breathing Apparatus User Instructions Article No 2014234 Issue D 12 2005...

Page 2: ...FACEMASK 12 3 7 1 All Facemasks 12 3 7 2 Facemasks with a Web Harness 12 3 7 3 Facemasks with a Net Harness 13 3 8 POSITIVE PRESSURE TEST 13 3 9 WHISTLE TEST 14 3 10 AIRLINE AND DECONTAMINATION ATTACH...

Page 3: ...the tasks being undertaken and the hazards likely to be encountered Please refer to National Regulations for guidance Adequate protection may not be provided in certain highly toxic atmospheres The ap...

Page 4: ...lations Unless otherwise specified the contaminants shall not exceed the permissible exposure level National regulations must be observed The mineral oil content shall be such that the air is without...

Page 5: ...ese instructions and national regulations These instructions cannot replace an accredited training course run by fully qualified instructors in the proper and safe use of SCOTT breathing apparatus Ple...

Page 6: ...89 Chiswick High Road London W4 4AL United Kingdom Please call Scott Health and Safety Limited for further apparatus approval details This manual contains user instructions for single cylinder twin cy...

Page 7: ...2 62 8 8 12 0 Note Only cylinders in the shaded areas above are suitable for use with Pro Pak Duo in the twin cylinder configuration The total apparatus weight must not exceed 18 kg when fully charged...

Page 8: ...ith the IRIS data communications system the warning whistle and pressure gauge are incorporated within the IRIS unit The warning whistle sounds when pressure in the cylinder falls to 55 bar 5 bar The...

Page 9: ...detailed in Section 1 2 9 FACEMASKS Pro Pak is approved for use with Vision 3 PanaSeal PanaVisor and Pro Mask PP full facemasks all of which conform to EN 136 Class 3 All are available with five poin...

Page 10: ...e airline connector is in good condition and that it connects securely to the Pro Pak pigtail iii The air supply conforms to EN 132 see Section 1 3 Compressed Air Airline Supplies iv The Pro Pak airli...

Page 11: ...ndition Screw the cylinder connector firmly into the cylinder valve outlet Should it become necessary to adjust the size of the cylinder band i Ensure that the clamp mechanism is unlocked and in the o...

Page 12: ...emoval ie the last to be removed is the first to be replaced 10 Slide a fully charged cylinder along the backplate and through the loosened cylinder band Position the cylinder outlet through the cylin...

Page 13: ...LE CYLINDER Pro Pak Duo can be adapted to accommodate either one or two cylinders Conversion is a straightforward process in which no tools are required To convert from Duo to single cylinder applicat...

Page 14: ...al To convert from single cylinder to Duo cylinders carry out the reverse of the above sequence of operations 3 5 RESET DEMAND VALVE 1 Press the black rubber reset button on the side of the DV and che...

Page 15: ...ervice 3 7 DV AND FACEMASK 3 7 1 All Facemasks 1 Check that the facemask is clean and undamaged 2 Check that the orange O ring on the DV outlet is clean and in good condition 3 Fit the DV to the facem...

Page 16: ...8 POSITIVE PRESSURE TEST 1 With the cylinder valve open insert a finger under faceseal and check for a steady outward flow of air Remove finger and allow mask to re seal 2 Hold breath for ten seconds...

Page 17: ...ment does not leak 6 DO NOT use attachments that show signs of excessive wear or damage or that leak excessively 7 Replace dust caps 3 11 RSM ATTACHMENTS 1 Remove RSM dust caps and attach a rescue mas...

Page 18: ...on the shoulder strap ends until the apparatus fits comfortably then close the waistbelt and tighten the slide buckle Note If the waistbelt is closed first tightening the shoulder straps will pull up...

Page 19: ...o the chin cup and pull the mask onto the face Grasp the pull strap at the rear of the net harness and pull the net over the head 2 Tighten harness side straps DO NOT over tighten 3 Inhale deeply to a...

Page 20: ...the cylinder valve s is are fully open and that the pressure gauge shows that there is sufficient air 2 Turn on the DV bypass knob and check for a steady flow of air into the mask Close the bypass kn...

Page 21: ...Release the handwheel locking mechanism and close the cylinder valve s 4 Open the DV bypass knob to depressurise the system then turn the bypass to OFF 5 Release the waistbelt buckle slacken shoulder...

Page 22: ...cle Numbers 2008247 and 2008248 respectively Pump dispensers are available for the above under Article Numbers 1017672 1 litre and 1017670 5 litres TriGeneTM disinfecting wipes are available from Scot...

Page 23: ...ations in a Breathing Apparatus Logbook available from Scott Health and Safety Limited under Article Number 1034745 Information recorded usually includes Name and address of employer responsible for t...

Page 24: ...st be kept up to date and available for inspection Please see Section 6 3 for details 7 2 ANNUALLY Pro Pak must be returned for a workshop service annually and for a major workshop service at six year...

Page 25: ...Scott Health and Safety Limited Pimbo Road West Pimbo Skelmersdale Lancashire WN8 9RA United Kingdom T l 44 0 1695 711711 Fax 44 0 1695 711775...

Reviews: