background image

PRO-PAK 

3

 

2.  APPARATUS 

DESCRIPTION 

2.1  GENERAL 

Pro-Pak

  is  an  open  circuit,  self-

contained,  compressed  air  Breathing 

Apparatus  (BA)  for  use  by  fire-fighters 

and  in  industrial  applications  where  a 

high  level  of  respiratory  protection  is 

required. 
Standard  versions  of 

Pro-Pak

  feature  a 

mechanical  pressure  gauge  and  whistle 

mounted on the left-hand shoulder strap. 

Versions  specifically  intended  for  use  by 

fire-fighters 

are 

available 

which 

incorporate 

the 

IRIS

 

data-

communications system. 

Pro-Pak

  is  approved  to  the  following 

European Standards: 

 

EN  137  :  1993  -  Self-contained 

Breathing Apparatus. 

 

PrEN 137 : 2002 - Including Annex 

A, 

Self-contained 

Breathing 

Apparatus  classification:  Type  2  - 

Fire Fighting. 

 

EN  139  :  1995  -  Self-contained 

Breathing  Apparatus  with  airline 

attachment  when  there  is  no 

intermediate split connection in the 

MP  airline  between  DV  and 

Pressure Reducer. 

 

EN  139  :  1995  -  Excluding 

requirements  of  clause  6.7.2,  Self-

contained Breathing Apparatus with 

airline attachment when there is an 

intermediate split connection in the 

MP  airline  between  DV  and 

Pressure Reducer. 

Pro-Pak

  is  'CE'  marked  in  accordance 

with  EEC  Directive  EC/686/1986  plus 

amendments. 

NOTIFIED BODIES: 

Inspec International Ltd (No. 0194) 

Upper Wingbury Courtyard, 

Wingrave, Aylesbury, 

Buckinghamshire, 

HP22 4LW, 

United Kingdom. 

British Standards Institute (No. 0086) 

389 Chiswick High Road, 

London, 

W4 4AL, 

United Kingdom. 
Please  call 

Scott  Health  and  Safety 

Limited

  for  further  apparatus  approval 

details. 
This  manual  contains  user  instructions 

for  single  cylinder,  twin  cylinder  (

Duo

versions  and  versions  for  use  with 

compressed air airlines. 

2.2  HARNESS 

The 

Pro-Pak

  harness  is  made  from 

flame-retardant

 

Kevlar

TM

  and 

Nomex

TM

The  buckles  are  manufactured  from 

stainless  steel,  chromium-plated  steel  or 

brass; and the press-studs from brass or 

nickel-plated brass. 
For  wearer  comfort,  a  lumbar  pad  or  full 

back pad is provided. Both are fabricated 

from flame-retardant material and packed 

with  flame  retardant,  closed  cell  foam. 

The  lumbar  pad  is  held  in  place  by  four 

press-studs.  The  full-length  pad  is  held 

by press studs and the harness straps. 

2.3  CYLINDER BAND 

Pro-Pak

  can  be  configured  for  use  with 

one  or  two  (

Duo

)  200,  207  or  300  bar, 

steel  or  fully  wrapped  aluminium  carbon 

fibre composite cylinders (see 

Table 3

). 

Cylinders  are  secured  to  the  lightweight 

backplate  by  a  webbing  cylinder  band 

and a cylinder valve retainer (CVR). 
The  webbing  cylinder  band  is  secured 

around the cylinder(s) by a hinged, clamp 

mechanism  with  a  thumb-operated 

release  tag  that  prevents  accidental 

opening.  The  band  can  be  adjusted  to 

accept  the  range  of  cylinders  listed  in 

Table 3

. The clamp mechanism facilitates 

replacement  of  similar  size  cylinders 

without cylinder band adjustment. 

Pro-Pak  Duo

  cylinder  bands  can  easily 

be  altered  by  the  wearer  (no  tools 

required)  to  mount  a  single  cylinder, 

centrally on the backplate. 
 

Summary of Contents for PRO-PAK

Page 1: ...PRO PAK Self contained Breathing Apparatus User Instructions Article No 2014234 Issue D 12 2005...

Page 2: ...FACEMASK 12 3 7 1 All Facemasks 12 3 7 2 Facemasks with a Web Harness 12 3 7 3 Facemasks with a Net Harness 13 3 8 POSITIVE PRESSURE TEST 13 3 9 WHISTLE TEST 14 3 10 AIRLINE AND DECONTAMINATION ATTACH...

Page 3: ...the tasks being undertaken and the hazards likely to be encountered Please refer to National Regulations for guidance Adequate protection may not be provided in certain highly toxic atmospheres The ap...

Page 4: ...lations Unless otherwise specified the contaminants shall not exceed the permissible exposure level National regulations must be observed The mineral oil content shall be such that the air is without...

Page 5: ...ese instructions and national regulations These instructions cannot replace an accredited training course run by fully qualified instructors in the proper and safe use of SCOTT breathing apparatus Ple...

Page 6: ...89 Chiswick High Road London W4 4AL United Kingdom Please call Scott Health and Safety Limited for further apparatus approval details This manual contains user instructions for single cylinder twin cy...

Page 7: ...2 62 8 8 12 0 Note Only cylinders in the shaded areas above are suitable for use with Pro Pak Duo in the twin cylinder configuration The total apparatus weight must not exceed 18 kg when fully charged...

Page 8: ...ith the IRIS data communications system the warning whistle and pressure gauge are incorporated within the IRIS unit The warning whistle sounds when pressure in the cylinder falls to 55 bar 5 bar The...

Page 9: ...detailed in Section 1 2 9 FACEMASKS Pro Pak is approved for use with Vision 3 PanaSeal PanaVisor and Pro Mask PP full facemasks all of which conform to EN 136 Class 3 All are available with five poin...

Page 10: ...e airline connector is in good condition and that it connects securely to the Pro Pak pigtail iii The air supply conforms to EN 132 see Section 1 3 Compressed Air Airline Supplies iv The Pro Pak airli...

Page 11: ...ndition Screw the cylinder connector firmly into the cylinder valve outlet Should it become necessary to adjust the size of the cylinder band i Ensure that the clamp mechanism is unlocked and in the o...

Page 12: ...emoval ie the last to be removed is the first to be replaced 10 Slide a fully charged cylinder along the backplate and through the loosened cylinder band Position the cylinder outlet through the cylin...

Page 13: ...LE CYLINDER Pro Pak Duo can be adapted to accommodate either one or two cylinders Conversion is a straightforward process in which no tools are required To convert from Duo to single cylinder applicat...

Page 14: ...al To convert from single cylinder to Duo cylinders carry out the reverse of the above sequence of operations 3 5 RESET DEMAND VALVE 1 Press the black rubber reset button on the side of the DV and che...

Page 15: ...ervice 3 7 DV AND FACEMASK 3 7 1 All Facemasks 1 Check that the facemask is clean and undamaged 2 Check that the orange O ring on the DV outlet is clean and in good condition 3 Fit the DV to the facem...

Page 16: ...8 POSITIVE PRESSURE TEST 1 With the cylinder valve open insert a finger under faceseal and check for a steady outward flow of air Remove finger and allow mask to re seal 2 Hold breath for ten seconds...

Page 17: ...ment does not leak 6 DO NOT use attachments that show signs of excessive wear or damage or that leak excessively 7 Replace dust caps 3 11 RSM ATTACHMENTS 1 Remove RSM dust caps and attach a rescue mas...

Page 18: ...on the shoulder strap ends until the apparatus fits comfortably then close the waistbelt and tighten the slide buckle Note If the waistbelt is closed first tightening the shoulder straps will pull up...

Page 19: ...o the chin cup and pull the mask onto the face Grasp the pull strap at the rear of the net harness and pull the net over the head 2 Tighten harness side straps DO NOT over tighten 3 Inhale deeply to a...

Page 20: ...the cylinder valve s is are fully open and that the pressure gauge shows that there is sufficient air 2 Turn on the DV bypass knob and check for a steady flow of air into the mask Close the bypass kn...

Page 21: ...Release the handwheel locking mechanism and close the cylinder valve s 4 Open the DV bypass knob to depressurise the system then turn the bypass to OFF 5 Release the waistbelt buckle slacken shoulder...

Page 22: ...cle Numbers 2008247 and 2008248 respectively Pump dispensers are available for the above under Article Numbers 1017672 1 litre and 1017670 5 litres TriGeneTM disinfecting wipes are available from Scot...

Page 23: ...ations in a Breathing Apparatus Logbook available from Scott Health and Safety Limited under Article Number 1034745 Information recorded usually includes Name and address of employer responsible for t...

Page 24: ...st be kept up to date and available for inspection Please see Section 6 3 for details 7 2 ANNUALLY Pro Pak must be returned for a workshop service annually and for a major workshop service at six year...

Page 25: ...Scott Health and Safety Limited Pimbo Road West Pimbo Skelmersdale Lancashire WN8 9RA United Kingdom T l 44 0 1695 711711 Fax 44 0 1695 711775...

Reviews: