Scotsman SLE400R User Manual Download Page 14

Initial Start Up

Note: If the first batch of cubes are not all uniform
discs, some ice machine cleaner should be added
to the reservoir.

1. After ice has been harvested, but before new
cubes begin to form, switch the ICE/OFF/WASH
switch to WASH.
2. Add 4 oz. of ice machine cleaner to the
reservoir. Allow unit to operate that way for 10
minutes.
3. Switch ICE/OFF/WASH switch to OFF
4. Shut the water supply off.
5. Remove the splash guard, and drain the
reservoir by removing the drain elbow.
7. Replace all parts, turn on the water and
move ICE/OFF/WASH switch to ICE. The next
batch of ice should be uniform.

13. Check harvest. The machine will have to
harvest all of the cubes before it goes back into the
freeze cycle.

14. Check operation of the bin control circuit by
holding ice on the bin control tube in the bin.

If the ice maker does not stop within 1 minute,
while keeping ice on the thermostat, rotate the bin
thermostat shaft counter clockwise until the ice
maker does stop. Remove the ice from the
capillary tube; the ice maker should restart within 2
minutes. If it does not, rotate the adjusting shaft
clockwise until the machine starts.

15. Replace all the panels. The ice machine is now
ready for automatic operation.

Electrical Sequence:

Freeze Cycle:

During the first part of the freeze cycle, the ice
machine compressor, fan motor and water pump
are operating.

Assume the bin thermostat is open (low ice), relay
K1 will NOT have power thru its coil and K1
contacts 6-2 will be closed, connecting power to
the ice size thermostat and the liquid line valve coil.

The ice size thermostat contact 2-3 are closed,
connecting power to the fan motor and the pump
motor.

The Harvest Termination Thermostat is closed to
NC, but there is no power thru it.

The ice size thermostat heater is on, and the
compressor contactor coil is energized.

Harvest:

In the harvest cycle, the compressor is operating,
and the hot gas valve is energized. The fan and
and pump are off. The bin thermostat is still open.

The when the ice near the ice size thermostat
sensing tube grows large enough to force water
over the sensing tube, that tube looses heat, and
at 38

o

F. contacts 2-3 open and 2-1 close.

This removes power from the water pump and
remote fan and connects power to the relay coil.
When the relay coil has power, it connects power
to the hot gas valve coil.

The harvest termination switch is closed, and
power flows thru it to the relay coil. This keeps the
relay energized, even when the ice size thermostat
switches contact position as a result of ice falling
away from the sensing tube.

The unit stays in the harvest cycle until the
thermodisc on the suction line warms up to 55

o

F.,

At that time the defrost themodisc switches to NO
and the harvest cycle is terminated. If the bin
thermostat is still open, relay K1 will still not have
power and the unit will go back into the freeze
cycle. If relay K1 has power, it shuts off the ice
machine by cutting power to the liquid line valve,
after the unit pumps down, the low pressure
control shuts off the compressor.

Whenever there is ice on the bin thermostat, it
closes a circuit to the coil of relay K1 and stops the
ice making process at the end of a harvest cycle.

The crankcase heater is on at all times.

Siphon Tube Schematic

U-Tube Adjusted

Here = No Purge

Siphon Breaker Hole

U-Tube Here =

Maximum Purge

Water Level

At Harvest

Water Level With

Pump ON

Water Inlet

1/8 - 1/4

Bottom of

Reservoir

Elbow

Drain Outlet

SLE400R

January 1995

Page 14

Summary of Contents for SLE400R

Page 1: ...warning symbol where it appears in this manual It is an alert for important safety information on a hazard that might cause serious injury Keep this manual for future reference This manual was printe...

Page 2: ...s used to determine wire size and type per the National Electric Code Note Do not connect this refrigeration system to a used condenser circuit Only the condenser and line set specified for this machi...

Page 3: ...factured with the highest regard for safety and performance They meet or exceed the standards of UL NSF and CSA Scotsman assumes no liability or responsibility of any kind for products manufactured by...

Page 4: ...itions Have the water tested Acidic water or alkaline water will both cause corrosion Dissolved solids cannot be filtered out Softened water is not recommended Never use de ionized water Reverse osmos...

Page 5: ...ea 3 Locate and uncoil a portion of the bin thermostat capillary tube Route the end of the capillary tube into the plastic tube in the base of the ice machine next to the compressor and through the bi...

Page 6: ...nd of the capillary tube thru the tube watch the capillary as it comes out of the base line it up with the inlet hole of the thermostat bracket and push it into the hole Move the cabinet of the ice ma...

Page 7: ...kit place the stainless steel adapter onto the top of the dispenser Follow all directions included with the kit 8 After the ice machine has been placed on the dispenser remove the front panel and unc...

Page 8: ...igid and meet local code Traps in the bin drain line without vents ahead of them will cause poor draining The bin drain must be vented if there is a long horizontal run 5 or more The reservoir drain m...

Page 9: ...condenser and to the ice machine Be certain that there is no metal to metal or tight tube to tube contact between the liquid and discharge lines Coil excess tubing inside the building in a horizontal...

Page 10: ...ections to the wires in the junction box A ground screw is provided in the junction box Follow All Local Codes This Unit Must Be Grounded Usually a licensed electrician will be required to connect the...

Page 11: ...l 8 Is the ice machine connected to a 230 volt electrical power supply and is the ice machine the only load on that circuit 9 Has all of the shipping material been removed from the inside of the cabin...

Page 12: ...e control adjustment ICE OFF WASH switch Control box Ice Thickness Control ICE OFF WASH Switch Bin Thermostat Water Distributor Pan Bin Thermostat Bracket Water Inlet Valve Strainer Water Pump Control...

Page 13: ...he ICE OFF WASH switch to ON 11 The remote fan motor will begin to turn and warm air will be discharged from the top of the remote condenser 12 The water temperature in the reservoir will soon be 320...

Page 14: ...motor and the pump motor The Harvest Termination Thermostat is closed to NC but there is no power thru it The ice size thermostat heater is on and the compressor contactor coil is energized Harvest In...

Page 15: ...r 1 Mix the bleach and water using the ratio of two ounces of bleach to two gallons of water 2 Wipe all interior surfaces of the ice storage bin with the bleach and water 3 Allow to air dry To Remove...

Page 16: ...e 17 Remove the water distributor pan 18 Mix a sanitizer solution of 1 ounce of household bleach to 2 gallons of warm 95o F 115o F water 19 Wash the splash guard and the water distributor pan with the...

Page 17: ...mote condenser Water Water flows into the ice machine from its inlet connection at the back of the cabinet through the inlet water valve and into the reservoir The water in the reservoir is pumped up...

Page 18: ...Discharge Pressure In Harvest 130 150 PSIG Typical Compressor Amp Draw 4 5 during freeze cycle 5 6 during the harvest cycle Compressor Copeland RS64C1E CAV 214 Thermostatic Expansion Valve Superheat i...

Page 19: ...ive TXV or compressor Unit off due to low pressure pump down control open Check liquid line valve coil for power and or continuity No ice is made compressor is operating No water due to water turned o...

Page 20: ...ess than 550 F Warm up air or move machine Lack of heat during harvest due to water flowing thru water cooled condenser Replace water regulating valve Lack of heat during harvest due to lack of refrig...

Page 21: ...Replace valve if temps are nearly equal Compressor inefficient Check replace compressor Cubes are wrong size shape Ice size thermostat not adjusted properly Adjust ice size thermostat use gauge shipp...

Page 22: ...he ice size thermostat with the proper part number following the above steps from 9 1 Primary Resistor Heater 1 Disconnect electrical power 2 Disconnect the primary resistor s yellow wire from termina...

Page 23: ...rge hose from pump discharge port 8 Remove pump from ice machine 9 Reverse above steps to replace Inlet Water Valve The valve may plug up from minerals in the water and should then be cleaned rather t...

Page 24: ...iquid line dryer is required Polyol ester oil absorbs water very easily and when the system is opened for service it must be re sealed as soon as possible 15 minutes maximum Special leak detection equ...

Reviews: