Installation
For The Electrician
This unit must be on a separate 230 volt AC 60
cycle single phase power supply. The maximum
fuse size for this circuit is listed on the nameplate,
and per the nameplate use fuses, or HACR circuit
breakers.
The remote condenser fan motor is powered from
the ice machine, thru the junction box at the back
of the ice machine.
To make the electrical connections:
1. Remove the right top panel.
2. Remove the junction box cover.
3. Make the electrical connections to the wires in
the junction box. A ground screw is provided in the
junction box.
Follow All Local Codes - This Unit Must Be
Grounded. Usually a licensed electrician will be
required to connect the electrical service.
The remote condenser fan motor requires an
electrical connection in the ice machine junction
box. See wiring diagram.
Remote wiring must be in liquid tight or rain proof
conduit as required by local codes.
The fan motor voltage is 208-230.
An appropriate outdoor junction box may be
required to be added to the remote condenser.
Power Supply for Ice Maker
and Condenser
Junction Box
Remote Electrical
Connection
SLE400R BACK VIEW
SLE400R