Installation
This manual covers several models. The model
number on the product is located in two places, on
the back dataplate and on the model and serial
number tag, located behind the front panel. See the
illustration for the dataplate and serial tag locations.
Write the model and serial number of this product
here:
________________________________________
Write the day, month and year of initial start up
here:
________________________________________
Switch Bezel
All models ship with the On and Off switches front
accessible. If desired, the On and Off switches can
be covered up to prevent unauthorized use by
changing the bezel in the front panel’s trim strip. A
cover-up bezel ships loose with the machine.
To change bezels: Remove the front panel, and
refer to the instruction label on the inside of the
front panel. Push snaps of standard bezel in and
pull the bezel out of the front panel trim strip.
Locate other bezel. Push into the trim strip from the
front until it snaps into place. Return the front panel
to its original position and secure it to the cabinet.
Uncrate and Set Up
Begin with unpacking the ice storage bin. Remove
the carton, and using part of the carton as a
cushion, tip the bin on its back to remove the skid
and attach the legs or casters.
Return the bin to an upright position. Check the bin
top gasket for gaps and tears, fill any in with food
grade sealant prior to placing the ice machine on
the bin.
Install the bin top adapter or ice dispenser adapter,
if one is required for the application.
If the ice machine has not been unpacked, do so
now. Remove the carton from the skid. Lift the ice
machine off the skid directly onto the bin.
Note: The machine is heavy! Use a mechanical
hoist if necessary.
Secure the ice machine to the bin with the
hardware provided (two metal straps and 4 bolts).
Place the bin and ice machine in the selected
location and level it by adjusting the bin leg
levelers.
Plumbing Requirements
All models require connection to cold, potable
water. A hand actuated valve within site of the
machine is required. Air cooled models have a
single 3/4 gas BSPP inlet water connection.
Water cooled models have the same inlet fitting
plus an additional 3/8” FPT condenser inlet water
connection.
Water Filters
If connecting to water filtration, filter only the water
to the reservoir, not to the condenser. Install a new
cartridge if the filters were used with a prior
machine.
All models require drain tubing to be attached to
them. Air cooled models have a single ¾” FPT
drain fitting in the back of the cabinet. Water cooled
models have the same fitting plus an additional ½”
FPT drain fitting in the back of the cabinet.
Install new tubing when replacing a prior ice
machine, as the tubing will have been sized for the
old model and might not be correct for this one.
1.
Connect water supply to water inlet fittings.
3/8" OD tubing is recommended.
2.
Connect drain tubing to drain fittings.
3.
Route the drain tubing to building drain. Follow
local codes for air gap.
Drain Tubing:
March 2007
Page 7
C0322 through C1030
Air and Water Cooled Installation Manual
Warning: All models require connection to
potable water.
Summary of Contents for Prodigy C0522
Page 18: ......
Page 88: ...www scotsman ice com www scotsman ice it 17 3185 01 ...