When choosing the water supply for the MV
Cuber, consideration should be given to:
A. Length of run.
B. Water clarity and purity.
C. Adequate water supply pressures.
Since water is the most important single ingredient
in producing ice you cannot over emphasize the
three items listed above. Low water pressure,
below 1 bar may cause malfunction, of the
icemaker unit. Water containing excessive
minerals will tend to produce cloudy colored ice
cubes, plus scale build-up on parts in the water
system.
Heavily chlorinated water can be controlled using
charcoal or carbon filters.
DRAINS
AIR-COOLED MODELS: There is one 20 mm.
dia sump drain fitting at the back of the cabinet.
Insulations in high humidity areas is recom-
mended. The ideal drain receptacle would be a
trapped and vented floor drain.
WATER-COOLED MODELS: Besides the above
drain, a separate condenser drain must be run.
Connect it to the - 3/4'’ gas - condenser drain
connection at the back of the cabinet.
STORAGE BIN: A separate gravity type drain
needs to be run, similar to the air-cooled sump
drain. Insulation of this drain line is recom-
mended.
FOR THE ELECTRICIAN
ELECTRICAL CONNECTIONS
The unit come equipped with an electrical cord
for power supply. The lead wires must be
connected to an electrical plug that corresponds
to the local electrical codes and requirements or
to a separate two poles disconnect box with
opening to the contacts of about 3 millimeters.
The disconnect box shoulds be placed close to
the selected ice maker location to be easily and
prompt reached.
Undersized wiring or unproperly installed
electrical circuit will result in major problems and
malfunctions.
Voltage variations shoud not exceed ten percent.
IMPORTANT - All plumbing and electrical
connections must be made by licensed
plumbers and electricians, this one must
follow the electrical specifications printed
on the ice maker nameplate.
NOTE: All SCOTSMAN Cubers require a
neutral wire and a solid earth ground wire to
prevent possible severe Electrical Shock
Injury to individuals or extensive damage to
equipments.
machine, (the use of a mechanical lift is
recommended for this step). Align the two
machines cabinets, and using the 2 screw from
the top units, hardware package, fasten the two
units together at the side cabinets.
Then make use of the Stacking Kit KSC 12,
KSC 21, KSC 32 or KSC 50 to be mounted as per
fitting instructions included in their package,
respectively on MV 12, MV 21, on MV 32 and
MV 50 located in the bottom for proper conveying,
of the ice cubes made by the top unit, into the
storage bin.
With food grade silicone perfectly seal the edge
between the freezing compartment of the upper
machine and of the bottom machine so to avoid
any possible leak of water through the clearence
in between.
FOR THE PLUMBER
CONFORM TO ALL APPLICABLE CODES
WATER INLET
AIR-COOLED MODELS: The recommended
water supply is cold water, 3/8'’ O.D. copper
tubing, connected a - 3/4'’ gas - male fitting at the
back of the cabinet. Install a hand valve near the
machine to control the water supply.
1) Switch
2) Plug receptacle
3) Electrical plug
4) Water inlet
5) Shut-off valve
6) Water filter
7) Water outlet line
8) Bin water outlet line
9) Open vented water drain
10) Water outlet from the condenser:
water cooled version only.