Configuration:
A remote low side cuber system includes several
sub systems: an ice making section, a remote
compressor package, and a remote air cooled
condenser. Additionally, there are two models of
each sub-system and this manual covers all of
them.
The ice making sections are designed for use
indoors in a controlled environment. The remote
compressor packages and condensers are
designed to operate outdoors. Each sub-system
has limits for power, water and temperature.
Operational Limitations:
Minimum
Maximum
Air Temp (IMS)
50
o
F
100
o
F.
Air Temp (CU)
-20
o
F.
120
o
F.
Water Temp
40
o
F.
100
o
F.
Water Pressure
20 psi
80 psi
Voltage (IMS)
104
126
Voltage (CU)
198
253
IMS = Ice Making Section, CU= Condensing Unit
Do Not operate the machine in conditions beyond
these limitations. Doing so will void the warranty.
Scotsman ice systems are designed and
manufactured with the highest regard for safety
and performance. They meet or exceed the
standards of UL and NSF.
Scotsman assumes no liability of responsibility of
any kind for products manufactured by Scotsman
that have been altered in any way, including the
use of any part and/or other components not
specifically approved by Scotsman.
Scotsman reserves the right to make design
changes and/or improvements at any time.
Specifications and design are subject to change
without notice.
Warranty
Refer to the warranty coverage in effect when the
equipment was sold. Warranty statements are
included with each product.
Systems:
Each sub-system is a separate entity that carries
its own model and serial number. They must be
combined to create a remote cuber low side
system.
Eclipse
ä
600, 800, 1000
April 2002
Page 2
System Model
Number
Condensing Unit (CU)
Ice Making Section (IMS)
Compressor Package
Condenser
Model
Electrical
Model*
Electrical
Model
Electrical
Eclipse 600-42
CP686-32A
208-230/60/1
ERC680-32A
208-230/60/1
CME686RLS-1A 115/60/1
Eclipse 600-43
CP686-3A
208-230/60/3
Eclipse 800-42
CP886-32A
208-230/60/1
ERC680-32A
208-230/60/1
CME810RLS-1A 115/60/1
Eclipse 800-43
CP886-3A
208-230/60/3
Eclipse 1000-42
CP1086-32A
208-230/60/1
ERC1086-32A 208-230/60/1
CME810RLS-1A 115/60/1
Eclipse 1000-43
CP1086-3A
208-230/60/3
Notes: Voltage Codes are at the end of the model number. Codes read Voltage/Hertz/Phase. Those related
to these products include:
-1 = 115/60/1
-3 = 208-230/60/3
-32 = 208-230/60/1
-42 = 115/60/1 and 208-230/60/1 (separate units)
-43 = 115/60/1 and 208-230/60/3 (separate units)
System Information
*ER2C6810-32 is a two circuit remote condenser
and can be used with any of these systems.
Pre-charged tubing kits are required to
interconnect the IMS to the CP.
Interconnecting 24 volt control wire ships with the
CP unit.