Operational Characteristics 600 lb system
Cycle Times @ Condenser Temp/Cabinet Temp/Water Temp in degrees F
System Pressures @ Condenser Temp/Cabinet Temp/Water Temp in degrees F.
Headmaster maintains a minimum discharge
pressure during freeze of:
·
217 PSIG + 25, -15 PSIG
CPR Valve Setting: 55 - 60 PSIG.
Note: CPR allows a maximum low side pressure at
the CP unit’s compressor. Maximum only occurs
during harvest.
Refrigerant Charge
·
232 oz
Compressor Amps
·
Single Phase - 5
·
Three Phase - 3.5
Batch Weight
·
8 to 10 lb
Discharge Pressure Cut Out Switch
·
Cuts Out at: 450 PSIG
·
Resets at: 350 PSIG
Compressor: RS70C1E
Expansion Valves: 3
Eclipse
ä
600, 800, 1000
May 2002
Page 45
70/70/50
90/90/70
120/110/100
Freeze
16 to 20 minutes
20 to 23 minutes
35 to 37 minutes
Harvest
3 minutes
2 ½ minutes
1 ½ minutes
70/70/50
90/90/70
120/110/100
Suction at Ice Making Section, end of Freeze
34 to 40 PSIG
36 to 42 PSIG
42 to 48 PSIG
Suction at Ice Making Section, Harvest
80 to 90 PSIG
90 to 110 PSIG
130 to 150 PSIG
Discharge at Condensing Unit: Freeze
230 to 250 PSIG
240 to 260 PSIG
340 to 360 PSIG