background image

 

 

 

Sanitising 
 

NOTE. Sanitising 

of the water system is recommended to be done 

once every 6 months. 

 

1. Prepare in a plastic container the preferred sanitation solution as per manufacturer dilution using 
warm water (hand hot !!!) 

 Approx a 10% ratio is suggested. 

 

NOTE. Never mix the descaling solution with the sanitising solution. 
 

 

 

 

2. Follow the procedures as per the cleaning regime (from item 10 to item 14) just shortening the 
operation of the water pump 

‘clean

/rinse 

mode’ 

to 10 minutes for sanitising. 

 
 
3. Place again the evaporator cover and the unit service panels. 
 
4. Wipe clean and rinse the inner surfaces of the storage bin along with the cleaning of the ice level 
sensor on the inside of the unit storage bin before resuming normal ice making operation. 
 
5. At completion of the cleaning regime, 

place the unit into normal operational mode via the ‘clean’ 

switch (Position No (I), allow the unit to make 2 batches of ice to then dispense/

discard…………

 

 
 

ATTENTION. In case the ice cubes are cloudy-white and have an acidic taste, melt them 
immediately by pouring on them some warm water. This to prevent that somebody could use 
them. 
 
 

 
 
 

Summary of Contents for DXG 35

Page 1: ...n as to how cleaning and sanitizing of the dispensing ice machine is completed This does not replace the instruction given within the full service manual but to assist and supplement it Cleaning shoul...

Page 2: ...sive products such as steel wool pads acids etc Since these could damage the various surfaces In case of persistent stains normal abrasive detergents or products specific for stainless steel are readi...

Page 3: ...all ice cubes have been released from the evaporator ideally after a unit defrost harvest then switch OFF the machine at both Water electrical supplies 3 Dispense all the ice cubes stored from the bi...

Page 4: ...ot with a quantity of Ice Machine Cleaner based on 10 dilution rate ie 5 litres of water 500ml descaling acid WARNING The Ice Machine Cleaner Sanitiser contains harmful fluids Please refer to any supp...

Page 5: ...astic cup Once flushed out install again the sump Plastic cap 14 Pour over the evaporator two or three litres of clean potable water to rinse the evaporator platen 15 Switch ON again the electrical su...

Page 6: ...mode to 10 minutes for sanitising 3 Place again the evaporator cover and the unit service panels 4 Wipe clean and rinse the inner surfaces of the storage bin along with the cleaning of the ice level...

Page 7: ...Clean Priming Switch...

Page 8: ...Hubbard Systems offers suitable product for the use for cleaning sanitizing of all ice dispensers please call 01473 350045 for further detail and the appropriate MSDS data sheets...