Sanitising
NOTE. Sanitising
of the water system is recommended to be done
once every 6 months.
1. Prepare in a plastic container the preferred sanitation solution as per manufacturer dilution using
warm water (hand hot !!!)
–
Approx a 10% ratio is suggested.
NOTE. Never mix the descaling solution with the sanitising solution.
2. Follow the procedures as per the cleaning regime (from item 10 to item 14) just shortening the
operation of the water pump
‘clean
/rinse
mode’
to 10 minutes for sanitising.
3. Place again the evaporator cover and the unit service panels.
4. Wipe clean and rinse the inner surfaces of the storage bin along with the cleaning of the ice level
sensor on the inside of the unit storage bin before resuming normal ice making operation.
5. At completion of the cleaning regime,
place the unit into normal operational mode via the ‘clean’
switch (Position No (I), allow the unit to make 2 batches of ice to then dispense/
discard…………
ATTENTION. In case the ice cubes are cloudy-white and have an acidic taste, melt them
immediately by pouring on them some warm water. This to prevent that somebody could use
them.
Summary of Contents for DXG 35