NOTE.
With the system in CLEANING/RINSING mode, the water pump is the only component in
operation to circulate the cleaning solution in the entire water system.
12. Let the unit remain in the
CLEANING
mode for about 15 minutes then turn off/unplug again the
Machine.
NOTE.
The amount of Cleaner and the time needed for cleaning of the water system depends on the
units internal condition.
13. Ensuring that the unit is isolated at the master button switch, flush out the cleaning solution
from the sump reservoir by taking off the sump plastic cup. Once flushed out, install again the sump
Plastic cap.
14. Pour over the evaporator two or three litres of clean potable water to rinse the evaporator
platen.
15. Switch ON again the electrical supply to the machine.
With the machine in ‘clean mode’ t
he
water pump is again in operation to circulate the water in order to then rinse the entire water
system. Repeat this operation as per steps 13 and 14 twice more so to be sure no traces of descaling
solution remain into the water sump area.
16. Wipe clean and rinse the inner surfaces of the storage bin along with the cleaning of the ice level
sensor on the inside of the unit storage bin before resuming normal ice making operation by
switching the rocker switch to position (II).