COOL AIR INTAKE
WARM AIR DISCHARGE
IF BUILT IN, THIS SIDE
SHOULD BE TIGHT AGAINST
THE CABINET TO PREVENT
AIR RECIRCULATION
FOR THE INSTALLER
Location:
Prior consideration for the location shall include:
••
Indoors, with a minimum room temperature of
50
0
F. and a maximum room temperature of
100
0
F.
••
Water temperature to the machine should be
between 40
0
F. and 100
0
F.
••
Service Access. Allow enough space at the
back of the cabinet for the utilities to be
connected. Allow enough space for the
machine to be pulled out from its installed
location. Do not build a floor in front of the
machine that would prevent its removal.
••
Air circulation: The front panel MUST remain
unobstructed. Do not block with any type of
door or curtain.
If the unit is built in, it will pull air in from the right
side of the front panel, and exhaust it out the left
side of the front panel. If the left side of the
machine is left open, warm air will be
discharged from the left side panel.
CS60
January 1995
Page 3