Cube Size
Control
Cube Size Control Tube. Locate
and Secure in its Original
Position
REMOVAL AND REPLACEMENT
Bin Thermostat
1. Unplug the ice maker to disconnect electrical
power.
2. Remove screws and cabinet front panel.
3. Remove screws and control box cover,
disconnect electrical wires from bin thermostat
control.
4. Dismount bin thermostat from the control box
5. Remove rear panel.
6. Pull bin thermostat capillary line from tube in
ice storage bin. Remove complete control from
ice machine.
7. Replace with new control in reverse order of
removal.
Cube Size Control
1. Unplug the ice maker to disconnect electrical
power.
2. Remove screws and cabinet top, front, and
rear panels.
3. Pull knob from cube size control shaft.
Remove screws and control box cover to gain
access to the cube size control body. Remove
screws and dismount cube size control from
control box. Disconnect electrical wires from
cube size control.
4. At the top of the machine, unclip cube size
thermostat tube holder from evaporator, (retain
clips and tube assembly.) Pull cube size control
capillary tube from the tube, and remove
complete cube size control from the ice maker.
5. Insert capillary tube on new thermostat into
tube holder, be sure that the end caps are in
place.
6. Reverse the removal procedures to reinstall
the cube size control. Adjust as needed.
Refrigeration System
Any time the refrigeration system is opened, the
drier must be replaced, the system evacuated
and the exact charge measured into the system.
Any other procedure is NOT CORRECT, and will
result in substandard performance.
Electrical Shock Hazard.
Disconnect electrical
power before beginning.
CS60
January 1995
Page 16