WARNING
Protect the inflator from sand, keeping it inside the bag provided with the unit: if sand gets in, the
inflator may get jammed.
DEFLATION MODE (GE BTP only)
1. During deflation the valve must be kept open by a suitable adaptor: choose the correct one among the
supplied adaptors.
2. Install the chosen adaptor onto the hose.
3. Connect the other end of the hose to the deflation port (OUT).
4. Connect the pump to the power supply using one of the cables.
5. Press the ON push button.
6. During deflation the unit does not switch off automatically.
When the inflatable is completely deflated, press the OFF push button immediately to prevent overheating.
SAND FILTER MAINTENANCE (GE BTP only)
The inflator is equipped with a filter positioned under the deflation port (IN).
It is recommended to keep it clean for a longer life and higher efficiency of the inflator.
For maintenance:
• Loosen the two screws that hold the filter cover (deflation port – IN) in place.
• Lift the cover and remove the filter.
• Clean the filter with compressed air or replace it, if it is too dirty.
• Reinstall the cover by fastening the screws.
TROUBLESHOOTING
ACCESSORIES
Recommended accessories for use with your inflator are available from your local dealer or authorized service
center.
WARNING
The use of any accessories not recommended for use with this inflator could be hazardous.
PROBLEM
POSSIBLE CAUSE
POSSIBLE SOLUTION
Wrong connection of the power cord
Make sure polarity is correct
to the battery.
(red is positive).
No battery voltage.
Check the battery.
ON push button not ON.
Press ON push button.
Inflator is damaged.
Contact a SCOPREGA service center.
Wrong port connected.
Connect the inflation hose to the proper port.
Wrong pressure setting.
Adjust setting on the pressure knob.
.
Inflator will
not start
Inflator will not
inflate/deflate