GE 25 SL - GE 25 HP - GE 25 AC 

 

 

 

 

Instruction manual 

 

2. 

AVOID UNINTENTIONAL STARTING. 
Donʼt start the inflator with the inlet port in contact with dust or water. 

3. 

STAY ALERT. 
Watch what you are doing. Use common sense.  

4. 

CHECK DAMAGED PARTS. 
Before further use of the inflator, a guard or other part that is damaged should be carefully checked to determine that it will operate 
properly and perform its intended function.  

5. 

DO NOT  OPERATE  portable inflators  near flammable liquids  or  in gaseous  or  explosive  atmospheres.  Motors  in  these  inflators 
normally spark, and the sparks might ignite fumes.  

6. 

WARNING! RISK TO BREATHING! 
The  compressed  air  from  your  inflator  is  not  safe  for  breathing.  Never  inhale  air  from  your  inflator  or  from  a  breathing  device 
connected to the inflator.  

7. 

WARNING! RISK OF BURSTING. 
Inflate items only to their manufacturerʼs recommendations. Exceeding the pressure rating could cause them to explode resulting in 
personal injury.  

8. 

DO NOT LEAVE THE UNIT RUNNING UNATTENDED. 
Overinflation could result in serious injury and property damage.  

9. 

WARNING! RISK OF UNSAFE OPERATION. 
Do not modify or attempt to repair. Never drill into or make any modifications to the inflator or its attachments.  

10.  Never carry the inflator by the hose. 

 

IMPORTANT CHARGING NOTES 

 

1. 

Longest life and best performance can be obtained if the battery is charged when the air temperature is between 18°- 24°C (65°F 
and 75°F). 
DO NOT charge  the  battery  in an  air temperature  below  +40°F  (+4.5°C),  or  above  +105°F  (+40.5°C).  This  is important  and  will 
prevent serious damage to the battery.  

2. 

The charger and battery may become warm to touch while charging. This is a normal condition, and does not indicate a problem.   

3. 

DO NOT immerse charger in water or any other liquid. 

 

WARNING: DO NOT ALLOW ANY LIQUID TO GET INSIDE THE CHARGER. ELECTRIC SHOCK MAY RESULT 

 

4. 

DO NOT attempt to charge the battery with any chargers other than the ones in this manual. 
The charger and battery are specifically designed to work together.  

5. 

The charger is not intended for any use other than charging the battery in the Inflator. 
Any other uses may result in risk of fire, electric shock or electrocution.  

6. 

Make sure cord is located so that it will not be stepped on tripped over, or otherwise subjected to damage or stress.  

7. 

Do not operate charger with a damaged cord or plug.  

8. 

Do not operate the charger if it has received a sharp blow, been dropped, or otherwise damaged in any way.  

9. 

Do not disassemble charger. Incorrect reassembly may result in a risk of electric shock, electrocution or fire.  

10.  Never use another products charger to charge this product. Always use identical replacement parts only. 
11.  To operate the inflator insert the fuse, located inside the carry bag, first. 
12.  When charging the inflator check that the green light on the pressure gauge turns ON for full charge (do not consider LED on the 

110-240V adaptor). 

13.  Charging time may take up to 8 hours. 

 

INTRODUCTION 

 
GE 25 is a new portable, high efficiency electric Inflator that stands alone for reliability and functions. The inflator operates in two stages 
which can be identified by the noise of the turbine at the beginning followed by the piston. The inflator switches from turbine to piston 
automatically. The pump starts when the ON push button is pressed and automatically switches off when the pressure set on the gauge 
is reached. The OFF button stops the unit when pressed by the operator.  
GE 25 in the versions SL and HP is fully portable since a battery is included in the unit. In case of battery LOW it is possible to connect 
the unit to the 110-240 Vac battery charger. 
To operate the GE 25 AC a 120 V - 60 Hz or 230V - 50 Hz power supply is needed, as indicated on the data label. 
The  unit  is  protected  against  high  temperature.  In  case  of  external  high  temperature  conditions  or  in  case  of  continuous  running,  the 
inflator will automatically stops and a RED Light on the GAUGE will signal the status. When the RED light  goes off, it will be possible to 
restart the unit. 

 
SUGGESTED USES: 

 

Large rigid inflatable like SUPs / Inflatable Boats / Kayak / Kites / etc. 

 

Rafts / air mattresses / swimming pool floats / etc.  

 
CHARACTERISTICS: 

 

Capacity   

 

 

 

450 L/min (turbine) - 250 L/min (compressor) 

 

Max Pressure  

 

 

 

1500 mbar (22 psi) 

 

Pressure setting 

 

 

 

Gauge with auto shut off  

 

Modes 

 

 

 

 

Inflate and deflate 

 

Safety Fuse 

 

 

 

40 Amps 

 

Battery Charging port  

 

 

Jack Type (only to GE 25 SL and GE 25 HP) 

 

Power cord 

 

 

 

L= 3 m (only to GE 25 AC) 

Summary of Contents for GE 25 SL

Page 1: ...g operation 9 Do not incinerate the battery even if it is severely damaged or is completely worn out The battery can explode in a fire Check with local codes for possible special disposal instructions 10 If any leakage of liquid from the battery cells occurs discontinue use immediately and return the battery to your local Bravo Service Center or authorized service facility 11 Never attempt to open...

Page 2: ...t in risk of fire electric shock or electrocution 6 Make sure cord is located so that it will not be stepped on tripped over or otherwise subjected to damage or stress 7 Do not operate charger with a damaged cord or plug 8 Do not operate the charger if it has received a sharp blow been dropped or otherwise damaged in any way 9 Do not disassemble charger Incorrect reassembly may result in a risk of...

Page 3: ...move the hose from the storage location Press the air hose clips to the port OUT to inflate Fit the air hose adaptor to the inflatable OPERATING THE INFLATOR To INFLATE connect the hose to the outlet port Set the desired limit on the pressure knob Only for GE 25 AC switch the Main Switch on I Press the ON push button The unit will start and the light on the gauge will turn GREEN The inflator will ...

Page 4: ...one of the same size 40 A Unit is damaged Contact SCOPREGA Service Center Will not inflate Wrong port connected Connect the air hose to the proper port Wrong setting on the pressure knob Adjust settings Battery LOW with RED or YELLOW light ON Connect the unit to a battery charger ACCESSORIES Recommended accessories for use with your inflator are available from your local dealer or authorized servi...

Page 5: ... intorno al gonfiatore durante il funzionamento 22 Non bruciare o distruggere la batteria anche se gravemente danneggiata o completamente esaurita La batteria può incendiarsi Verificare con le autorità locali il modo di smaltimento 23 Non utilizzare la batteria se si verificassero uscite di liquido e riportarla al centro assistenza autorizzato più vicino 24 Non tentare di aprire la batteria Non ut...

Page 6: ...7 Non utilizzare il caricatore con il cavo o la spina danneggiati 8 Non utilizzare il caricatore se ha preso un colpo è caduto o si è danneggiato in qualsiasi modo 9 Non smontare il caricatore Il rimontaggio non corretto può causare scossa corto circuito o incendio 10 Non utilizzare mai altri caricatori per caricare quest apparato Utilizzare sempre solo pezzi di ricambio originali 11 Al primo funz...

Page 7: ...pento l interruttore generale solo GE 25 AC Prendere il tubo dalla borsa Collegare il tubo dell aria alla bocca per gonfiare OUT Montare l adattatore più idoneo per il gonfiabile ACCENSIONE DEL GONFIATORE Per GONFIARE collegare il tubo alla bocca d uscita Impostare sul manometro la pressione desiderata Solo per il GE 25 AC premere l interruttore generale I Premere il tasto ON L apparato si avvia e...

Page 8: ... è danneggiato Rivolgersi a un centro di assistenza SCOPREGA Il gonfiatore non gonfia Errato collegamento del tubo Collegare il tubo dell aria alla bocca corretta Errata impostazione della pressione Correggere l impostazione della pressione Batteria SCARICA con led giallo o rosso ON Ricaricare le batterie con il caricabatteria 110 240V ACCESSORI Gli accessori raccomandati per il vostro gonfiatore ...

Reviews: