Scope DataPage UHF MK2 Radio Paging System
DPMK2/6
8
07/05
Program Parameters
The standard models are factory pre-set and should not under any circumstances be adjusted by the
customer. The factory settings can be viewed for the purposes of verification when ordering additional
components etc.
The system parameters are protected from accidental change by password control. To enter the system
type:
( 72765 then press ENTER
This is the default password. To alter this to a password of your own choice, see
5: Changing the
Password
You can escape from this programme at any time by pressing CANCEL. Upon acceptance of the password
the screen will change to :
1: Setup 2: Inputs
3: Phone 4: Serial
1: Setup
Press key 1. The screen changes to:
BASE PAGER ID:
>
0090000
(The number shown is just an example)
To change the base pager ID enter the new number and press ENTER. In the event that you make a
mistake press CANCEL and start again.
After pressing ENTER, the screen display will change to prompt for the default beep type:
DEFAULT BEEP:
>
1
You may enter a number in the range 1-4 which will correspond to the pager beep codes A, B, C, D
respectively. Note, not all pagers are equipped to respond to transmitted beep codes. Press ENTER to
confirm or CANCEL to return to the start.
After pressing ENTER, the screen display will change to prompt for the transmission data speed:
TRANSMIT SPEED:
>
1200 bps
Press key 1 to select 512 baud, key 2 to select 1200 baud or key 3 to select 2400 baud. Press ENTER to
return to the programming menu.
2: Inputs
Press key 2. The screen changes to:
INPUT COUNT 0-2
>
Select the number of dry contacts required: either 0, (none), 1 (DC1) or 2 (DC1 and DC2).
After pressing ENTER, the screen will change to:
ACTIVATE
STATE:
:
Normally
Open