background image

ConneXions CX9DC   DC power, Two Port Version

 

 

CX9DC   Issue 

 

Page

 

7 of 13  

 

Section 2: System Operation

 

 

Confirmation of power connection is by way of the red LED on the base of the transcoder 
console. 
 
Confirmation of transmit is provided by way of the momentary green LED on the base of the 
transcoder console. 

 

Sending data in the correct format (see Technical Section, 

Calling Pagers

) will invoke 

transmitted messages to the relevant pagers. 

 

 
Problems and Fault Finding. 
 

Check and re-check the data cable connections. This, together with an incorrect 

 

signalling format, result in more faults than any other problem. 

 

Check that the communications baud rate of the host equipment matches that of the 
Connexions COM ports. The default baud rate settings on the Connexions are: 

  

COM1 = 1200 baud, COM2 = 9600 baud (check configuration data supplied with 
your order, see label on inside of chassis). 

 

Check that the pagers are at least 3 metres from the transmitter and aerial. 

 

Under certain conditions it is possible to flood the pager receivers and corrupt the 

 data 

received. 

 
4    

Check that the pagers have the battery installed with the correct polarity and are 
correctly powered up. Check the pager baud rate and frequency matches the 
Connexions transmitter (see label on inside of chassis plate). 

 

Check that the red power LED on the base of the transcoder is lit. If not, remove the 
power cord and check that 12V DC is available from the source supply.  

 
6  

Check that the green LED lights for the duration of the transmission. If not, go back 

 

to the data cabling and re-check the signal format. 

 
7  

Check that the aerial is correctly installed.

 

 

 
 
IMPORTANT: Isolate mains before removing cover. Internal access and adjustments strictly 
limited to authorised service personnel only. 
 
 

Radio Transmission Baud Rate 

 
This is set at the factory to suit the pagers supplied and will normally be set at either 512 or 
1200 baud. Please refer to the separate configuration sheet and/or delivery note supplied 
with your unit.

 

 
 
 
 

Summary of Contents for Connexions CX9DC

Page 1: ...pe Communications UK Ltd Quantum House Totnes Devon TQ9 5AL United Kingdom Tel 44 0 1803 860700 Fax 44 0 1803 863716 www scope uk com Connexions CX9DC Radio Paging Transcoder DC Two Port Version Installation User Manual ...

Page 2: ...this equipment is governed by our standard terms and conditions of sale which can be found on the reverse of all order acknowledgements proforma invoices delivery notes price lists and invoices Alternatively these can be provided on request Faxed proforma invoices and quotations refer to conditions available upon request Important Safety Information Scope products are designed to operate safely wh...

Page 3: ...arranty This product is warranted as free from defects of workmanship and materials for a period of one year from the original purchase date During this time if there is a defect or malfunction of this product Scope will with proof of purchase repair or replace at it s discretion any defective parts free of charge This does not include where the adjustments parts and repair are necessary due to ci...

Page 4: ...iven location it is important to take into account the range of operation that you require to obtain from your system The standard transmitter can quite easily provide ranges of up to a mile or more and will provide excellent propagation on most sites covering a considerable area with just a 1 4 wave antenna BNC terminated connected directly to the unit For coverage where exceptionally difficult o...

Page 5: ...ack plasterboard b Metal mesh or wire reinforced glass c Metal sheeting large mirrors or suspended ceilings d Lift shafts All of the above can reflect radio waves and thereby reduce the capability of the transmitter to perform its desired functions 6 The circuit boards within this equipment may be harmed by Electrostatic Discharge ESD Installers should ensure that both themselves and the system s ...

Page 6: ...COM1 COM2 COM1 COM2 RS232 SERIAL PORTS 9 way D Type Plug PIN SIGNAL DIRECTION 1 N C 2 RECEIVE DATA RX IN 3 TRANSMIT DATA TX OUT 4 DATA TERMINAL READY DTR OUT 5 GROUND GND 6 N C 7 REQUEST TO SEND RTS OUT 8 CLEAR TO SEND CTS IN 9 5V 100mA max for Scope peripherals As information passes only from the host equipment to the ConneXions transcoder you will only need to read the DTR line which if high sho...

Page 7: ...ConneXions CX9DC DC power Two Port Version CX9DC Issue 1 Page 6 of 13 DIAGRAM 1 ...

Page 8: ... the pagers are at least 3 metres from the transmitter and aerial Under certain conditions it is possible to flood the pager receivers and corrupt the data received 4 Check that the pagers have the battery installed with the correct polarity and are correctly powered up Check the pager baud rate and frequency matches the Connexions transmitter see label on inside of chassis plate 5 Check that the ...

Page 9: ...ny of these contacts will cause irreparable damage This unit can support up to 8 dry volt free contacts on PL1 which when shorted to ground will send a pre programmed message to a particular pager address which could be to an individual a group or all pager operatives at the same time These messages are pre programmed and can only be changed by qualified service personnel The trigger time required...

Page 10: ...two minutes if still active For customers who wish to connect directly to PL1 the pinout arrangement on the 9 way D plug is shown below PL1 9 way D Plug Dry Contact No 1 1 2 3 3 5 4 7 6 2 7 4 8 6 9 8 5 GROUND Test Calls a test call message can be sent every 10 seconds This feature is very useful for site surveys and range testing The default is dry contact no 1 ...

Page 11: ... Effective Radiated Power ERP Service Information If you experience a problem with your equipment you must first telephone our service hotline where we may request that you undertake a few simple checks If a problem still remains we will arrange collection of your system by overnight carrier at our expense Upon receipt we will endeavour to service or replace the system within 24 working hours and ...

Page 12: ...nel better than 200nW 4 5 KHz deviation TX Baud Rate 512 or 1200 RF Standards applied EN 300 224 Type Designation ECOLINK Notified Body Ref No 0891 EMC Standards applied EN 300 682 General Ports RS232 serial on COM1 COM2 Optional 8 way dry contact I F Comms Baud Rate 600 to 9600 software adjustable Footprint mm 330 L x 190 W x 70 D max dependent on system configuration excluding aerial Scope s pol...

Page 13: ...1000 to 1 999 000 If for example a base address of 0100 000 is applied to a transcoder the first real pager number will 0100 008 followed by 0100 016 and so on Logical pager numbers are normally used on systems fitted with the telephone interface and those which are interfaced to personal computers The algorithm would perform the following function For example take the logical pager number of 123 ...

Page 14: ...en LED lighting for the same period to show that data is being transmitted The time taken to transmit the message is dependent upon the pager baud rate For 512 baud this is approximately 4 seconds whilst at 1200 baud the time is approximately 2 seconds The unit can accept sequential data at 9600 baud which will be buffered and dealt with as soon as the preceding transmission has ended The RTS line...

Reviews: