ConneXions CX9DC   DC power, Two Port Version

 

 

CX9DC   Issue 

 

Page

 

2 of 13  

Preface 

 
Installation

 

 

Installation must only be undertaken by an Approved contractor, who shall ensure that all work is 
carried out in compliance with National Wiring Regulations. For mains powered equipment, a readily 
accessible isolating fuse or switched socket must be located within 1 metre of the equipment. 
 

No User Serviceable Parts

 

 
Alteration or modification to any part of this equipment, without the prior written consent of the 
manufacturer, will invalidate all Approvals and Warranties attaching to the equipment. Further liability 
for the operation of the equipment, under the applicable law, will pass to the user, who will absolve the 
manufacturer of any further responsibility for it’s correct operation and use. 
 

Liability 

 
Scope does not accept liability for any damage or injury, howsoever caused as the result of misuse of 
this equipment. It is the responsibility of the user to ensure that the equipment is operated in the 
manner for which it was intended and that it is the correct item of equipment for the required task. 
 

Warranty 

 
This product is warranted as free from defects of workmanship and materials for a period of one year 
from the original purchase date. During this time, if there is a defect or malfunction of this product, 
Scope will, with proof of purchase, repair or replace at it’s discretion any defective parts, free of 
charge. This does not include where the adjustments, parts and repair are necessary due to 
circumstances beyond the control of Scope, including but not limited to fire or other casualty, accident, 
neglect, abuse, abnormal use or battery leakage damage. 
 

WARNING! No User Serviceable Parts  

 
Alteration or modification to any part of this equipment, without the prior written consent of the 
manufacturer, will invalidate all manufacturer approvals and warranties.  No adjustments can be 
undertaken except by qualified and licensed persons as authorised by Scope.  

 

This product complies with the essential requirements of the R&TTE Directive 1999/5/EC 

Copies of the Declaration of Conformity covering this product can be obtained from Scope at:  

Quantum House, Steamer Quay, Totnes TQ9 5AL United Kingdom.  

 

Do not discard.  At end of life this equipment must be sent to an authorised waste treatment centre. 

Contact Scope at the above address for further details. 

 

 

© Scope Communications UK Ltd, 2008 All Rights Reserved. E & OE. 

 

 
 
 
 
 
 
 
 
 
 

Summary of Contents for Connexions CX9DC

Page 1: ...pe Communications UK Ltd Quantum House Totnes Devon TQ9 5AL United Kingdom Tel 44 0 1803 860700 Fax 44 0 1803 863716 www scope uk com Connexions CX9DC Radio Paging Transcoder DC Two Port Version Installation User Manual ...

Page 2: ...this equipment is governed by our standard terms and conditions of sale which can be found on the reverse of all order acknowledgements proforma invoices delivery notes price lists and invoices Alternatively these can be provided on request Faxed proforma invoices and quotations refer to conditions available upon request Important Safety Information Scope products are designed to operate safely wh...

Page 3: ...arranty This product is warranted as free from defects of workmanship and materials for a period of one year from the original purchase date During this time if there is a defect or malfunction of this product Scope will with proof of purchase repair or replace at it s discretion any defective parts free of charge This does not include where the adjustments parts and repair are necessary due to ci...

Page 4: ...iven location it is important to take into account the range of operation that you require to obtain from your system The standard transmitter can quite easily provide ranges of up to a mile or more and will provide excellent propagation on most sites covering a considerable area with just a 1 4 wave antenna BNC terminated connected directly to the unit For coverage where exceptionally difficult o...

Page 5: ...ack plasterboard b Metal mesh or wire reinforced glass c Metal sheeting large mirrors or suspended ceilings d Lift shafts All of the above can reflect radio waves and thereby reduce the capability of the transmitter to perform its desired functions 6 The circuit boards within this equipment may be harmed by Electrostatic Discharge ESD Installers should ensure that both themselves and the system s ...

Page 6: ...COM1 COM2 COM1 COM2 RS232 SERIAL PORTS 9 way D Type Plug PIN SIGNAL DIRECTION 1 N C 2 RECEIVE DATA RX IN 3 TRANSMIT DATA TX OUT 4 DATA TERMINAL READY DTR OUT 5 GROUND GND 6 N C 7 REQUEST TO SEND RTS OUT 8 CLEAR TO SEND CTS IN 9 5V 100mA max for Scope peripherals As information passes only from the host equipment to the ConneXions transcoder you will only need to read the DTR line which if high sho...

Page 7: ...ConneXions CX9DC DC power Two Port Version CX9DC Issue 1 Page 6 of 13 DIAGRAM 1 ...

Page 8: ... the pagers are at least 3 metres from the transmitter and aerial Under certain conditions it is possible to flood the pager receivers and corrupt the data received 4 Check that the pagers have the battery installed with the correct polarity and are correctly powered up Check the pager baud rate and frequency matches the Connexions transmitter see label on inside of chassis plate 5 Check that the ...

Page 9: ...ny of these contacts will cause irreparable damage This unit can support up to 8 dry volt free contacts on PL1 which when shorted to ground will send a pre programmed message to a particular pager address which could be to an individual a group or all pager operatives at the same time These messages are pre programmed and can only be changed by qualified service personnel The trigger time required...

Page 10: ...two minutes if still active For customers who wish to connect directly to PL1 the pinout arrangement on the 9 way D plug is shown below PL1 9 way D Plug Dry Contact No 1 1 2 3 3 5 4 7 6 2 7 4 8 6 9 8 5 GROUND Test Calls a test call message can be sent every 10 seconds This feature is very useful for site surveys and range testing The default is dry contact no 1 ...

Page 11: ... Effective Radiated Power ERP Service Information If you experience a problem with your equipment you must first telephone our service hotline where we may request that you undertake a few simple checks If a problem still remains we will arrange collection of your system by overnight carrier at our expense Upon receipt we will endeavour to service or replace the system within 24 working hours and ...

Page 12: ...nel better than 200nW 4 5 KHz deviation TX Baud Rate 512 or 1200 RF Standards applied EN 300 224 Type Designation ECOLINK Notified Body Ref No 0891 EMC Standards applied EN 300 682 General Ports RS232 serial on COM1 COM2 Optional 8 way dry contact I F Comms Baud Rate 600 to 9600 software adjustable Footprint mm 330 L x 190 W x 70 D max dependent on system configuration excluding aerial Scope s pol...

Page 13: ...1000 to 1 999 000 If for example a base address of 0100 000 is applied to a transcoder the first real pager number will 0100 008 followed by 0100 016 and so on Logical pager numbers are normally used on systems fitted with the telephone interface and those which are interfaced to personal computers The algorithm would perform the following function For example take the logical pager number of 123 ...

Page 14: ...en LED lighting for the same period to show that data is being transmitted The time taken to transmit the message is dependent upon the pager baud rate For 512 baud this is approximately 4 seconds whilst at 1200 baud the time is approximately 2 seconds The unit can accept sequential data at 9600 baud which will be buffered and dealt with as soon as the preceding transmission has ended The RTS line...

Reviews: