6.4.15.
READER_CNTLESS_RF_SWITCH
This escape command can be used to retrieve/set the RF state of SCL01X.
The default RF field state is ON.
The input buffer shall contain 2 bytes
Byte #
Value
Description
B0
0x96
Escape command code
B1
0x00
Switch RF Field OFF
0x01
Switch RF Field ON
0xFF
Get current field state
After the RF is turned off, to turn the RF ON again, card connect shall be done in direct mode.
If B1 of the input buffer is 0x00 or 0x01 the output buffer is
Output buffer
NULL
If B1 of the input buffer is 0xFF, the output buffer is a BYTE buffer with 2 possible values
Output buffer
Description
0x01
RF field is OFF
0x00
RF field is ON
6.4.16.
READER_CNTLESS_RAW_CFG
This escape command switches SCL01X to raw mode.
When SCL01X is in raw mode it only polls for one type of contactless card.
SCL01X is by default not in this mode and therefore READER_CNTLESS_RAW_XMIT would
fail.
The input buffer contains 2 bytes
Byte #
Value
Description
B0
0x97
Escape Function code
B1
0x00
Type A will be use for further
transmissions in raw mode
0x01
Type B will be use for further
transmissions in raw mode
The output buffer is
Output buffer
NULL
Once SCL01X is in raw mode commands can be sent using READER_CNTLESS_RAW_XMIT
escape command.
Summary of Contents for SCL01X
Page 2: ......
Page 7: ...7 3 4 Snap on card holder 78 ...
Page 36: ...SCL01X REFERENCE MANUAL 36 Results into the following memory mapping ...
Page 75: ...SCL01X REFERENCE MANUAL 75 7 3 Annex C Mechanical drawings 7 3 1 Top casing ...
Page 76: ...SCL01X REFERENCE MANUAL 76 7 3 2 Bottom casing ...
Page 77: ...SCL01X REFERENCE MANUAL 77 7 3 3 Cradle ...
Page 78: ...SCL01X REFERENCE MANUAL 78 7 3 4 Snap on card holder ...