9.
Check off, Send Lines ends with line feeds, Echo
typed characters locally boxes. Then click OK. On
the Properties screen click OK. Click on Call but-
ton Icon.
10. Below is a list of commands that can be used to
change the Parameters on the SmartDirect 2:
Configurable on the SmartDirect 2:
-
Unique ID (supplied by manufacturer)
-
Modem IP address (supplied by customer on site
survey)
-
Gateway IP address (supplied by customer on
site survey)
-
Net mask IP address
-
DNS server1 IP address (supplied by customer on
site survey)
-
DNS server2 IP address (supplied by customer on
site survey)
-
TCP server IP address (supplied by SCK)
-
TCP server port (supplied by SCK)
-
TCP server ID (Not used at this time)
-
TCP server password (Not used at this time)
-
Network server name is used for GPRS version
(installed at factory)
-
Network ID is used for GPRS version (installed at
factory)
-
Network password is used for GPRS version
(installed at factory)
-
ISP provider number is used for GPRS version
(installed at factory)
-
Modem type (GPRS or Ethernet)
-
Connection interval (Minimum time between
connections to the server.)
-
Silence timeout (Maximum time between trans-
actions.)
-
Retry timeout: (Minimum time delay between
command retries.)
-
Mode (configure or initialize or shutdown)
i.
Configure: Device must be put into this
mode to change parameters.
ii.
Initialize: Initialize the modem with saved
parameters.
iii. Shutdown: prepare the device for powering
off.
-
Battery power (on or off)
i.
On: Device uses the battery when line power
is removed.
ii.
Off: Device does not use the battery.
-
Reload defaults (Factory default settings will
be restored)
These parameters may be configured over the serial
connection locally using the following commands:
set:[parameter]=[value]
used to change a
parameter
get:[parameter]
used to return a parameter
value
send:[string to send]
used to send commands
directly to the socket modem
report
‡
provides a dump of system settings and
information
[parameter] = configurable parameter name
[value] = a string representing the new value.
(example “172.168.1.1”)
To reload factory defaults the user shall use the “set:”
command format with the exception that the
“=[value]” will be omitted.
The report and get commands may be used at any-
time.
In order to change a parameter, the device shall first
be placed into configuration mode (set:mode=con-
figure) which will go into effect when the device is
not currently connected to the host (i.e. the device is
idle or in error modes). Once in configuration mode,
the “set” commands shall be used to change parame-
ters.
To return to normal operation and load all of the
changes, the mode shall be changed to initialization
(set:mode=initialize) by the user. The modem shall
be reloaded using the new parameters.