There is a blank screen on
the display when switching.
The display does not
support the resolution of
the video source.
Switch again.
Manage the EDID data
manually to make the
resolution of the video source
automatically compliant with
the output resolution.
Cannot control the device
by control device (e.g. a
PC) through RS232 port.
Wrong connection.
Check to ensure the
connection between the
control device and the unit.
Wrong RS232
communication
parameters.
Type in correct RS232
communication parameters:
Baud rate: 9600; Data bit: 8;
Stop bit: 1; Parity bit: none.
Broken RS232 port
Send it to authorized dealer
for checking.
Note:
If your problem persists after following the above troubleshooting steps, seek
further help from authorized dealer or our technical support.