Schweigen SCC1200-SP Installation Manual Download Page 22

Page 22

9. Specification

1156

655

700

1200

179

66

179

655

700

Summary of Contents for SCC1200-SP

Page 1: ...www schweigen co nz RANGEHOOD INSTALLATION GUIDE UM422G 12S...

Page 2: ...__________________________________________________ 10 Cleaning the Interior ________________________________________________________________________________________ 11 Cleaning the Exterior __________...

Page 3: ...nd the lasting value of your rangehood We trust that you will enjoy your new Schweigen rangehood Please always retain your proof of purchase to aid in any warranty queries If you are unable to locate...

Page 4: ...not intended for use by person s including children with reduced physical sensory or mental capabilities or lack of experience and or knowledge Unless the person has been given supervision or instruc...

Page 5: ...by a qualified technician and that the indicated instructions and local regulations in force are met using materials that are compliant with the applicable legislation 11 The company will not be resp...

Page 6: ...d with soft cloth and non corrosive detergent Do not leave the rangehood wet after cleaning or use please keep rangehood dry IMPORTANT Never attempt to repair this appliance by yourself Always refer t...

Page 7: ...e oil could overheat and catch fire 2 Never flamb any foods beneath the rangehood The flames could cause a fire 3 Before carrying out any operation inside the rangehood unplug the appliance from the e...

Page 8: ...ed for heavy frying or heavy cooking 3 x 150mm Outlets optional only Remote Lamp For GU10 fittings please twist to remove Reducer For Isodrive 650 only Filter LED Indicator Panel Extraction Sheets Mai...

Page 9: ...ntrol On Off Use this button for activating and deactivating the motor The starting speed of the motor is 1 The number of lights showing on the LED Indicator Panel from left to right relates to the sp...

Page 10: ...eaned every 3 6 weeks or after 40 hours of use Disconnect electricity connection before maintenance and cleaning process To remove the filter press handle and remove it through the front guide bend it...

Page 11: ...can use high quality cleaning and protection products eg Steel Kleen to clean your rangehood WARNING Make sure that the electrical power is off The recommended detergent is a solution of water and a...

Page 12: ...place turn clockwise to secure the light bulb NOTE Light bulb should sit flush after being installed Do not over push the lamp holder as it may cause the light bulb to stick out If this has occurred...

Page 13: ...ventilation Regulations concerning the expulsion of air must be met at all times It is strongly recommended that the rangehood be installed centrally over the cooktop WARNING If the user decides to in...

Page 14: ...e external motor system with the rangehood can be connected at this stage or after the rangehood has been secured Place the rangehood in the section determined by the ceiling mounts and secure by scre...

Page 15: ...installing Install threaded rods onto the beam and drill holes at the four corners on the rangehood adjust the nuts to level the unit Connect the external motor system with the rangehood NOTE Please m...

Page 16: ...y available for Isodrive 1600 motor please attach it the motor 1 Isodrive Motor 1 Roof Seal Kit Dektite Support Straps Motor Power Lead Male Plug Rangehood to Motor Lead Female Plug Attach Flexi Duct...

Page 17: ...roof space Note Isodrive motor does not include roof seal kit and support straps Weather shield only available for Isodrive 1600 motor Please attach it to the motor 1 A Connect them with a high qualit...

Page 18: ...uce vapours rapidly This prevents the filters from gradually warming up and increases the chance of condensation forming There are many variables that can contribute to the condensation problem associ...

Page 19: ...t be a constant flow of air into the cooking area to avoid the creation of a depression which can affect the rate of aspiration Follow the advice from the instructions for induction systems with regar...

Page 20: ...connected to grounded plug and turned on Check motor switch Please ensure that there is power to the rangehood and the rangehood is switched on Check lamp switch Lamp switch should be at on position...

Page 21: ...r inside the rangehood Faulty Installation It is not the responsibility of Schweigen Home Appliances to rectify any incorrect installations A service call out fee will be charged for any Schweigen tec...

Page 22: ...Page 22 9 Specification 1156 655 700 1200 179 66 179 655 700...

Page 23: ...and motor have been installed as per the instruction guides in order for optimal performance Schweigen Home Appliances has presented this information in good faith to all their retailers and distribu...

Page 24: ...24 141 322 Australia 8 3 4 Anzed Court Mulgrave 3170 Victoria Phone 1300 881 693 Email sales schweigen com au Web www schweigen com au New Zealand 5 Tolich Place Henderson Auckland 0610 Phone 0800 200...