4. Installation
Wall Installation
1. Remove the Endline Isodrive 1350 Motor System
from the packaging.
2. Undo the 2 screws holding front grille and the
deflector, and remove them from housing (See
figure 1A, pg.10).
3. Remove the foam packaging material that is
behind the grille.
4. Remove the motor from the housing and set
safely aside before proceding with the installation:
Lift the motor mounting bracket side flanges up
and over the locating stops and remove the motor
assembly (See Figure 1B and Figure 2 on page 11).
5. Cut a wall aperture with measurements of 340mm
horizontally and 265mm vertically ensuring the
vertical cuts are at 90 degrees to the horizontal
cuts (See Fig.3, pg.12); if you have less than
40mm of depth in the wall aperture — or the wall
requires extra stability for the motor housing to
be installed — you may need to reinforce the wall
with noggins and use the optional rear mounting
bracket (See Optional Accessories,
page 7, and Figure 6, page 13).
6. To prevent water ingress apply a high quality
adhesive sealant to the rear of the front flange of
the motor housing, ensuring that the entire gap
between flange and wall is sealed (See Figure
1A, pg10; and Figure 4, pg.12) and secure motor
housing to wall using 4 attachment screws (see
figures 1A, 4, 5). Remove excess sealant that is
extruded from the joint.
Male plug to rangehood plug
Motor Housing
Male plug to
mains power
Rangehood
Female plug
to motor
200mm flexible ducting
Inside wall
Grille
Outside wall
1
OD refers to outside dimension.
Installation Overview