Minimum Mounting Height

This fan unit is intended for mounting at a minimum 
height of 2.1 metres (measured to the lower part of 
the fan impeller) above a floor or the ground.

Avoidance of Back Flow

Care should be taken to avoid the back flow of gases 
into the room from the open flue of gas or other open 
fire appliances.

Replacement of supply cord

If the supply cord is damaged, it must be replaced by 
a service agent or suitably qualified person in order to 
avoid a hazard.

NOTE: 

Do not use with a timer.

Why Flexi-duct?

Some internet sites strongly recommend the 
use of rigid ducting over fully flexible ducting. 
This may well be the case with conventional 
rangehoods with internal motors but not with 
external motor rangehood.

Schweigen’s unique Isodrive system works in the 
opposite way to conventional rangehoods, pulling air 
through the hood and acoustically matched ducting, 
producing almost silent high volume flow. The use 
of a complete rigid or semi-rigid ducting system will 
allow an organ piping effect to occur; like a didgeridoo 
where a noise is produced at one end of a hollow rigid 
pipe and the noise is amplified out the other.

The Isodrive system drives the noise outside the 
house.

WARNING:

 

Installation without the use of at least the minimum 
recommended length of acoustically matched 
flexi-ducting in the system will void performance 
expectations. Any installation problem must be 
reported to Schweigen. Call outs relating to incorrect 
installation will result in a service fee direct to the 
customer. Schweigen takes no responsibility for 
problems caused by faulty installation, this may void 
warranty. 

A preferred installer list can be obtained from 
Schweigen website 

www.schweigen.com.au

 or 

by calling 

1300 881 693

.

2. Your Safety

Summary of Contents for Endline Isodrive 1350

Page 1: ...02 2018 V1 0 www schweigen com au INSTALLATION GUIDE Endline Isodrive System 1350...

Page 2: ...nce of the unit as well as important safety notes This will ensure your personal safety and the lasting value of your Isodrive system Please always retain your proof of purchase to aid in any warranty...

Page 3: ...tallation Overview ____________________________________________________________________________ 8 4 Motor Installation Wall Installation _______________________________________________________________...

Page 4: ...indicated on the rating label Before Installation We recommend this appliance to be installed or repaired by a qualified Schweigen Home Appliances technician Please see our website www schweigen com a...

Page 5: ...itable for connection to ducting runs with a minimum inlet area of 17 000mm2 and length up to 10m maximum check with supplier if longer duct length required Where possible flexible ducting must be ext...

Page 6: ...n the opposite way to conventional rangehoods pulling air through the hood and acoustically matched ducting producing almost silent high volume flow The use of a complete rigid or semi rigid ducting s...

Page 7: ...e ducting Approx 6 metres 200mm 210mm OD1 diameter 3 Bell mouth adopter ring 200mm 4 Back Draught Shutter Not included in the box Optional Accessories 5 Fire guard Part number P3024 6 Rear mounting br...

Page 8: ...tal cuts See Fig 3 pg 12 if you have less than 40mm of depth in the wall aperture or the wall requires extra stability for the motor housing to be installed you may need to reinforce the wall with nog...

Page 9: ...d into the mounted power outlet inside the housing see Fig 1A pg 10 Fig 1B Fig 2 pg 11 8 Install the Front Grille and Deflector and secure using grille attachment screws see Fig 1A pg 10 NOTE A Fire E...

Page 10: ...g through housing flange Ensure that flange perimeter is sealed against wall structure to prevent water ingress into building Vertical wall with suitable anchorage for housing Vertical wall with suita...

Page 11: ...over the locating stops Fan and shutter assembly Motor mounting bracket Stop Ensure shutter assembly engages into bellmouth when installing SIDE RAILS MOTOR ASSEMBLY SUPPORT Removal of Motor Assembly...

Page 12: ...draining Wall Wall Completely seal front flange to wall joint using high quality bonding urethane all four sides Completely seal front flange to wall joint using high quality bonding urethane all four...

Page 13: ...ions must be within 2mm of each other 296mm 472mm 472mm Fit screw from inside body Black dots cover screw holes Load plates Rear clamp assembly optional part Nuts Load plate Outer nut Figure 5 Figure...

Page 14: ...5mm deep Mesh Motor housing Normal grille Fire guard frame Fire guard frame 20mm deep 5 Installation optional Figure 7 Can be fitted to any installation with access to the front Attaching optional fir...

Page 15: ...Schweigen will take no responsibility for problems caused by faulty installation A list of preferred Schweigen installers can be obtained from the Schweigen website www schweigen com au Shallow Space...

Page 16: ...cting installed looped over hanging beams should be installed in such a manner as to ensure the changes of direction are gradual Support of the ducting with the use of hangers may be required see opti...

Page 17: ...liso1350 Fire Guard Optional P3013 Eliso1350 Deflector 1 P3012 Eliso1350 Grille 1 P3011 Eliso1350 Installation Plate Optional El Rmb Build Assembly Endline 1350 Rear Mounting Bracket Optional El Inlet...

Page 18: ...al of the faulty unit and installation of the new unit The customer is also responsible for any freight charges incurred in this change over process See Warranty Card for more information Disclaimer U...

Page 19: ...Page 19 Notes...

Page 20: ...1 322 Australia 8 3 4 Anzed Court Mulgrave 3170 Victoria Phone 1300 881 693 Email sales schweigen com au Web www schweigen com au New Zealand 5 Tolich Place Henderson Auckland 0610 Phone 0800 200 510...

Reviews: