Wiring the Fan
A means of disconnect must be incorporated in the fixed wiring in accordance with electrical codes
and standards.
DO NOT LIFT, CARRY, OR HANG FAN BY POWER CABLE. This could possibly cause the safety
disconnect system to disconnect power to the fan.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
For compliance with EMC standards the LF/SP Assembly must be installed as directed in the
installation manual. The EMC requirements apply to the final installation in its entirety, not to the
individual components used. As every installation is different, the recommended installation should
follow these guidelines as a minimum.
Note:
The use of the LF/SP Assembly is mandatory and will apply to Fan [CE]. However, for Fan [UL/
CSA] the LF/SP Assembly is additional optional equipment and is available upon request.
Electrical Installation
Installing the Hub Cover [with Lens]
1. Take hub cover [with optional lens if applicable], and place over the center hub and blade
profiles. Align the hole pattern up with clearance holes on each of the five blades.
2. Fasten hub cover with insert to fan assembly by threading five #8-32 X 1-3/8” long machine screws
through the clearance hole into each blade and tighten to secure.
3. Turn fan by hand to ensure that there are no obstructions with the hub cover.
1. Ensure all local electrical codes are met.
2. The motor is to be field-wired to a separate dedicated branch circuit.
3. The power cable must be secured to a solid point of the glu-lam, purlin, OWSJ, wood truss or
building structure. The power cable is to be fastened so there is absolutely no slack in line, in order
to allow the safety disconnect to function as designed.
4. The location of the input power [line] is labelled on the enclosure and should be drilled to
accommodate the appropriate gauge of wire required in accordance with the electrical codes
and standards.
5. The input power [line] will be wired into the LF/SP assembly as shown in the following illustration.
6. The outgoing power [load] that is coming out of the LF/SP Assembly and going to the fan must
also be wired as shown in the following illustration.
Power Wiring – 120/240 VAC 1 Phase Input
Installing the Optional LED Light Kit