infraSchwank D / calorSchwank D - shape U
12
Version
004
infr
a_
calor
D
shape
U Au
str
a
lia
43/13
Te
chni
cal spe
c
ification
su
bject to chan
ge
7 Technical
specification
Appliance
Automatic heating device, heat transfer
by mean of infrared dark radiation.
Fuel Types
Natural gas
Propane
Minimum connection pressure in front of valve
Attention!
Max. connection pressure
Natural Gas: 5.0kPa
Fig 8:
Measurements infraSchwank D / calorSchwank D 15U
and 20U (view from below)
Electrical connection
Single phase A.C. 230 V, N, PE - 50Hz (cycles)
(approx. 80 VA)
Power supply for the heater and fan are connected to
the socket of the burner box. To set the burner box
free of voltage, it is only necessary to remove the
plug of the power supply.
The connection cable for the lifting magnet of
2-stage gas combination valve must connect from the
connection box (230 V/50 Hz) to the provided luster
terminal inside of the burner unit.
The connection cable for the lifting magnet of
modulating gas combination valve must connect
direct from the modulation box to the lifting magnet.
The distance between modulation box and burner
unit should be < 1,5m.
Exhaust gas
Flue gas pipe connection Ø 100
Connection
at exit of tube
Gas connection
15-30U R=1/2’’ male
40U
R=3/4’’ male
Type 15-40U
Natural Gas
1.13kPa
LPG 2.75kPa
infraSchwank D / calorSchwank D 15U
(all dimensions in mm)
infraSchwank D / calorSchwank D 20U
(all dimensions in mm)
Detail A / B
Detail A
Cross dimensions at burner unit
15-40U
A=80mm
Detail B
Cross dimensions reflector
valid for all types
Summary of Contents for calorSchwank D 15U
Page 1: ...BROCSCH115 1...