background image

EN

Floor grinding machine DSM 450

4 Maintenance

18

3.2 Operation

Risk of damage and injury from uncontrolled
movement of the machine!
Before pressing the safety switch, the ma-
chine has to be held firmly by the handle of
the guide bar.

High-voltage electrical current can be fatal!
Do not allow the power line to be run over,
crushed or pulled on!

The direction of work always has to be away
from the socket / extractor unit.

1.

Hold the machine by the guide handle
[1, Fig. A/D].

T

The surface to be ground can now be machined.

2.

Press the safety switch [15, Fig. D] and hold.

3.

The drive is switched on and accelerates to the
speed set at the speed regulator [13, Fig. C].

4.

If necessary, use the speed regulator to adjust
the speed for the grinding conditions.

If surface mills are being used, the speed
may not exceed 50 %!

5.

For wet grinding, press the lever (water supply)
[14, Fig. D] according to the required amount of
water (empirical value).

3.3 Switching the machine off

Observe the safety instructions in Chapter 2.

Risk of injury from a still rotating ETX loca-
ting plate even after the machine is switched
off!
Only switch off the machine with the tools
resting on the floor.
The tool mount can otherwise still rotate idly

(run-on)

for several seconds after being swit-

ched off or the safety switch is released.

 

Release the safety switch [15, Fig. D].

T

The machine is switched off

Risk of injury from high voltage!
There is still residual voltage even after the
machine has been switched off.
The power supply has to be disconnected to
remove all voltage from the machine.

4 Maintenance

Observe the safety instructions in Chapter 2!

The operating and maintenance personnel
responsible for the machine must ensure that
no one can enter the machine"s danger zone
during operation or maintenance work.

Maintenance work may only be performed
by trained specialists! They must be familiar
with the dangers associated with such work,
protect themselves and avoid danger!

When working on the machine (set-up, main-
tenance, service, repair, cleaning, etc.), the
power supply of the machine has to be di-
sconnected from the mains

(disconnect power plug)

!

Perform cleaning and maintenance work in
accordance with the operating manual and
check the safety equipment for complete-
ness and functionality.

4.1 Customer service and spare parts

In case of customer service queries, replacement
parts or repairs, please contact the manufacturer. To
ensure your queries are dealt with as quickly as pos-
sible, always quote your machine data. These are
located on the machine s nameplate.

4.2 Tilting the machine

Before tilting the machine, always make sure
that it is on an even, level floor surface!

1.

Disconnect the power plug [2, Fig. A] from the
mains.

2.

If necessary, activate the lever [14, Fig. D] and
empty the tank [10, Fig. A].

3.

Swivel and lock the guide handle [1, Fig. A] in
the stretched position (

Chapter 3.1).

4.

Tip the machine and place it on the floor
(Fig. M).

Summary of Contents for DSM 450

Page 1: ...1 1 EN Floor grinding machine DSM 450 Translation of the original operating manual...

Page 2: ...2 2 Fig A 8 1 5 11 4 10 2 16 17 7 6 9 3 Fig E 8 4 5 7 6 18 Fig F 11 12 3 Fig B Fig C 13 8 19 14 Fig G 1 15 11 Fig D 10 20 Fig H...

Page 3: ...3 3 Fig I 23 24 25 27 28 26 Fig J 29 26 Fig K Fig L Fig...

Page 4: ...afety switch 16 E Water connection 17 E Connection to the dust extraction 18 F Plug connection 19 G Screws 20 H Bolt 23 I Polycrystalline diamonds PCD 24 I Metal bonded diamonds 25 I Synthetic resin b...

Page 5: ...or distributed in any form without the written permission of Schwamborn Ger tebau GmbH Liability or warranty is excluded if The instructions in the operating manual have not been observed The machine...

Page 6: ...essed by the machine need to be free of obstacles Warning signs Fig L M must be in a legi ble condition Risk of injury from rotating machine parts Limbs and clothing can be drawn in Proceed with the g...

Page 7: ...4 Either dry grinding Attach external dust extraction at the con nection to the dust extraction 17 Fig E or wet grinding Check the water level in the tank 10 Fig A and refill if necessary 5 Grip the g...

Page 8: ...tched off Risk of injury from high voltage There is still residual voltage even after the machine has been switched off The power supply has to be disconnected to remove all voltage from the machine 4...

Page 9: ...Set the machine upright swivel and lock the guide handle in standard position Chapter 3 1 All locating plates need to be equipped with complete surface mills of the same type The degree of wear on all...

Page 10: ...in the accompanying docu mentation The crane hook or lashing gear may only be attached at the specified position Fig L Wear safety shoes Wear safety gloves Suspended loads can fall or tip over cau si...

Page 11: ...r ropes When hoisting or transporting the machine with a vehicle or suitable transport device always make sure that the machine is secu red or strapped in with tension belts accor ding to regulations...

Page 12: ...he surface to be ground is too little Correct the distance between rubber lip and the surface to be ground Chapter 3 1 page 17 Grinding pattern is uneven Tools are loose Fasten tools g p Tools are dam...

Page 13: ...Low Voltage The following harmonised standards apply EN 292 1 EN 292 2 EN 13857 Safety of Machinery EN 60204 1 Electrical Equipment of Machines EN 50081 2 EN 50082 2 EN 61000 6 2 Electromagnetic comp...