6.3 - OPERATION

Domestic hot water production 

(Summer Mode)

Make sure that the selector 

(B)

 is 

positioned on (   )

Position the domestic hot water 

temperature knob 

(C)

 on the de-

sired temperature.

- completely to the left =

 35°C

  

- completely to the right =  

57°C

 

By adjusting the temperature of the domestic hot 

water at a temperature very close to that actually 

used,  you  will  avoid  mixing  hot  water  with  cold 

water, with management savings and significantly 

reducing the formation of limescale. 

By opening a hot water tap, the 

appliance is automatically activat-

ed and delivers water at the set 

temperature. 

During the sampling stage, the dis

-

play shows the temperature of the 

domestic hot water and the symbol 

) stays lit up.

Antifreeze protection

The boiler is equipped with an antifreeze protection system.

To activate the antifreeze function, position the 

two knobs as shown in the figure.

 

The antifreeze protection inter-

venes only if the boiler is powered 

electrically and if the gas valve is 

open.

If for some reason there is a power 

or gas failure, the antifreeze protec-

tion described above is not active. 

Heating 

discharge

For operation in heating mode the 

knob 

(B)

 must be positioned in the 

field shown in the figure, 

- In correspondence of MIN 

  the temperature is minimum = 

45°C

.

- completely to the right = 

78°C

If the heating system is equipped 

with a modulating room thermostat 

(TA mod), put the knob 

(B)

 in cen-

tral position.

During the heating stage, the dis

-

play shows the water temperature 

and the symbol ( 

 ) stays lit up

Complete decommissioning

To decommission the system, 

disconnect the boiler from the 

power supply by acting on the main 

switch.

In  the  event  of  complete  decom

-

missioning, the heating and hot 

water production modes as well 

as the antifreeze protection are 

completely disabled.

If  idle  for  long  periods,  close  the 

gas shut-off valve and cold water 

cock, if present

.

Summary of Contents for SWG

Page 1: ...SWG ENGLISH uSER S OPERATION INSTRUCTION ...

Page 2: ...ting safety of the appliance ATTENTION To tighten or loosen the screwed fittings use only appropriate fixed spanners Non compliant use and or inappropriate tools can cause damage e g water or gas leakage ATTENTION Indications for propane gas fired appliances Make sure that the gas tank has been deaerated before installing the appliance For state of the art tank venting contact the LPG supplier or ...

Page 3: ...ar and com bustion analysis must be performed every two years as per national law Should the appliance be sold or transferred to a new owner or if you move and leave the appliance always make sure that the instruction booklet accompanies it in order to be con sulted by the new owner and or installer The manufacturer will not be held liable in the event of damage to persons animals or objects resul...

Page 4: ...tion and heating temperature adjustment Positioning the knob in the field shown to the side indicates that the boiler is in Winter mode and adjusts the temperature of the heating circuit water The adjustment is between min 45 C and max 78 C C Domestic hot water temperature regulator Via this knob it is possible to ad just the domestic hot water inlet temperature Positioning the knob in the field i...

Page 5: ...he symbol on the display display the error code when the boiler operation is block due to a permanent fault activating the symbol on the display Thermometer If on the display the symbol is lit up the temperature in dicated is that relating to the water for the heating circuit If on the display the symbol is lit up the temperature in dicated is that relating to the water for the domestic hot water ...

Page 6: ...sition the two knobs as shown in the figure The antifreeze protection inter venes only if the boiler is powered electrically and if the gas valve is open If for some reason there is a power or gas failure the antifreeze protec tion described above is not active Heating discharge For operation in heating mode the knob B must be positioned in the field shown in the figure In correspondence of MIN th...

Page 7: ...d flashing in place of the degrees centigrade for the error codes list see par 4 6 installation and maintenance instruction manual The user can intervene to restore proper operation only in the following cases System pressure too low How to elimi nate the fault Restore the correct pressure value by acting on the boiler filling valve for optimum operation the pres sure value should be within 0 8 an...

Page 8: ...feriore 52 C 29012 Caorso PC Italy e mail info schusterboilers com www schusterboilers com The manufacturer declines every responsibility for the possible inaccuracies if owed to errors of transcript or press Also reserves the right to bring those changes that it will hold necessary to it own products or profits without jeopardizing its essential characteristics ...

Reviews: