L - Burner in operation signal

This symbol indicates that the burn-

er is in operation. 

The symbol lights up when the boil-

er receives a request for heating or 

domestic hot water production.

F - Operation in heating mode

The symbol lights up when the 

boiler receives a request in heating 

mode. If a request for domestic hot 

water production is received at the 

same time, the light switches off.

G - Operation in hot water 

production mode

This symbol lights up when there 

is a request for domestic hot water.

I - Block signal

The symbol lights up when the 

burner safety device has inter-

vened, due to:

- No gas

- Failed ignition

In the first case, in which the burner 

will not light, one must check if the 

gas valve is open.

M - Fault signal

The symbol lights up on the display 

monitor when the boiler detects an 

operation anomaly or it is blocked 

due to a permanent fault. The code 

that identifies the cause is displayed 

in place of the degrees centigrade 

by pressing the unblock button (D). 

The symbol is also displayed by en-

abling the calibration function and 

flashes when changing parameters. 

D - Unblock button

By acting on this button for < 1 sec. 

one can:

-   restart the boiler after the burner 

safety device has intervened, ac-

tivating the symbol on the display  

-   display the error code when the 

boiler operation is block due to 

a permanent fault, activating the 

symbol on the display

Thermometer

If, on the display, the symbol 

 ) is lit up, the temperature in-

dicated is that relating to the water 

for the heating circuit

If, on the display, the symbol

 ) is lit up, the temperature in-

dicated is that relating to the water 

for the domestic hot water circuit.

A - Pressure gauge

Displays the water pressure inside 

the  heating  circuit;  this  pressure 

value must not be below 0.8/1 bar 

(when cold).

If the pressure drops below 0.8/1 

bar, one must restore the correct 

value by acting on the system fill

-

ing valve. This operation must be 

carried out when the boiler is cold.

6.2 - CHECKS BEFORE COMMISSIONING

1

Make sure the gas shut-off valve upstream of 

the boiler is open.

2 Check that any shut-off valves

for maintenance, on the flow and

return are open.

3 Check that the shut-off valve, for maintenance, 

on the domestic cold water inlet is open.

4 Check that the safety valves outlet has been 

connected to the drains.

5

Check that the boiler is powered electrically; 

the display (E) on the control panel must be 

lit up.

6 Check the water pressure on the boiler pres-

sure  gauge  (A);  for  optimum  operation,  the 

pressure  should  be  between  0.8  and  1  bar 

(with pump stopped).

 Should the pressure be lower than 0.7 bar with 

the system cold, restore pressure by opening 

the system filling tap (see par. 6.4).

Summary of Contents for SWG

Page 1: ...SWG ENGLISH uSER S OPERATION INSTRUCTION ...

Page 2: ...ting safety of the appliance ATTENTION To tighten or loosen the screwed fittings use only appropriate fixed spanners Non compliant use and or inappropriate tools can cause damage e g water or gas leakage ATTENTION Indications for propane gas fired appliances Make sure that the gas tank has been deaerated before installing the appliance For state of the art tank venting contact the LPG supplier or ...

Page 3: ...ar and com bustion analysis must be performed every two years as per national law Should the appliance be sold or transferred to a new owner or if you move and leave the appliance always make sure that the instruction booklet accompanies it in order to be con sulted by the new owner and or installer The manufacturer will not be held liable in the event of damage to persons animals or objects resul...

Page 4: ...tion and heating temperature adjustment Positioning the knob in the field shown to the side indicates that the boiler is in Winter mode and adjusts the temperature of the heating circuit water The adjustment is between min 45 C and max 78 C C Domestic hot water temperature regulator Via this knob it is possible to ad just the domestic hot water inlet temperature Positioning the knob in the field i...

Page 5: ...he symbol on the display display the error code when the boiler operation is block due to a permanent fault activating the symbol on the display Thermometer If on the display the symbol is lit up the temperature in dicated is that relating to the water for the heating circuit If on the display the symbol is lit up the temperature in dicated is that relating to the water for the domestic hot water ...

Page 6: ...sition the two knobs as shown in the figure The antifreeze protection inter venes only if the boiler is powered electrically and if the gas valve is open If for some reason there is a power or gas failure the antifreeze protec tion described above is not active Heating discharge For operation in heating mode the knob B must be positioned in the field shown in the figure In correspondence of MIN th...

Page 7: ...d flashing in place of the degrees centigrade for the error codes list see par 4 6 installation and maintenance instruction manual The user can intervene to restore proper operation only in the following cases System pressure too low How to elimi nate the fault Restore the correct pressure value by acting on the boiler filling valve for optimum operation the pres sure value should be within 0 8 an...

Page 8: ...feriore 52 C 29012 Caorso PC Italy e mail info schusterboilers com www schusterboilers com The manufacturer declines every responsibility for the possible inaccuracies if owed to errors of transcript or press Also reserves the right to bring those changes that it will hold necessary to it own products or profits without jeopardizing its essential characteristics ...

Reviews: