Maintenance and care
03.00|WDP-5X |en
63
•
Check the pneumatic clamping systems and the workpiece
direct clamping modules at regular intervals (at least every 2
weeks or after 200 clampings).
•
Carry out regular visual/functional checks.
In the case of visible damage or signs of malfunctions on the
clamping systems or the quick-change pallet system installed on
the WDP-5X-DSM 99-70 workpiece direct clamping module, shut
down the clamping systems immediately. The system may only be
commissioned again once the faults have been removed. For
example, by replacing the damaged module.
Maintenance and care for manual direct clamping module
WDP-5X-DSM 99-70-M and for manual compensation
module WDP-5X-ASM 99-70-Ø36-M
Ensure
•
that the actuating screw is not jolted on tightening.
•
that the maximum permissible tightening torque is not
exceeded.
•
that the assembly tool is positioned straight and not askew.
•
that the tightening screw is replaced every 2,000 clamping
cycles, depending on how long the clamping system is used.
•
When replacing the drive screw, the sleeve that is screwed on
the front at the access point to the drive needs to be removed.
The sleeve is fitted with a left-hand thread. The sleeve can be
unscrewed clockwise using a spanner wrench with two end
spigots that engage in the holes.
•
Unscrew the drive screw.
•
Clean all components.
•
Grease a new drive screw on the thread and then screw it in.
•
Screw in the sleeve with the thread locking device
counterclockwise.
•
Perform a functional check.