Technical data
16
03.00|ROTA TPS-K, ROTA TPS-Z |en
Technical data
Actuation pressure
6 bar
Pressure medium
Compressed air, compressed air quality according to
ISO 8573-1:7 4 4
Operating temperature
+ 5°C to + 60°C
Noise emission
≤ 70 dB (A)
Installation position
Any
ROTA TPS
125-26 / K 125-26 / Z 160-38 / K 160-38 / Z
ID no.
0816127
0816126
0816137
0816136
Stroke per jaw [mm]
3
3
4.2
4.2
Max. clamping force* [kN]
22
22
39
39
Air consumption per double stroke
[cm
3
]
2200
2200
4800
4800
Closing/opening time at 6 bar [s]
0.35
0.35
0.39
0.39
Weight [kg]
12
12
23
23
Max. jaw stroke [mm]
40
40
40
40
ROTA TPS
200-52 / K 200-52 / Z 250-68 / K 250-68 / Z
ID no.
0816147
0816146
0816157
0816156
Stroke per jaw [mm]
4.2
4.2
5
5
Max. clamping force* [kN]
68
68
105
105
Air consumption per double stroke
[cm
3
]
7800
7800
13200
13200
Closing/opening time at 6 bar [s]
0.85
0.85
0.89
0.89
Weight [kg]
34
34
60
60
Max. jaw stroke [mm]
54
54
70
70
ROTA TPS
315-90 / K 315-90 / Z 315-105 / K 315-105 / Z
ID no.
0816167
0816166
88000779 88000785
Stroke per jaw [mm]
5
5
5
5
Max. clamping force* [kN]
140
140
80
80
Air consumption per double stroke
[cm
3
]
16400
16400
10800
10800
Closing/opening time at 6 bar [s]
1.2
1.2
1.5
1.5
Weight [kg]
82
82
72
72
Max. jaw stroke [mm]
76
76
70
70
* Clamping force is the arithmetic sum of the individual forces
occurring at the chuck jaws at a distance of "H" at 6 bar