Assembly
03.01/3-Finger Centric Gripper PZN-plus/en
27
NOTICE
Sensor can be damaged during assembly.
•
Do not exceed the maximum tightening torque of 10 Ncm for
the set screws.
NOTE
Ferromagnetic material changes the switching positions of the
sensor. For example: Adapter plate made of ordinary steel.
At ferromagnetic adapter plates:
•
The module must firstly be mounted on the adapter plate
•
Then, the positions of the magnetic switch have to be set
A
A
l
1
l
2
1
2
Fig. 11
1 Slide or turn in the magnetic switch (1) into the groove until it
bears against the stop (2) (if available).
2 If there is no terminal stop, then slide the magnetic switch ac-
cording to dimension l2 (bottom edge of gripper up to front
side of sensor) or according to dimension l1 (bottom edge of
gripper up to double arrow on sensor) and then clamp with
the mounting screw.
Assembling the sensor