Basic safety notes
12
3.00 | PRH | Assembly and Operating Manual | en | 389327
The product may only be used in the following locations if
additional measures are taken:
• In locations with a high level of ionizing radiation
• In locations with difficult operating conditions, e.g., due to
caustic fumes, gases, oils or chemicals
• In facilities requiring special monitoring, e.g., in particularly at-
risk areas
The product must also not be used in potentially explosive zones.
If the product is subjected to unacceptably large impacts or
vibrations, suitable measures must be taken to reduce the
amplitude or acceleration of such disturbances. Vibration-damping
or vibration-absorbing systems are to be used in such cases.
Tests with regard to
ambient conditions
Tests with regard to mechanical ambient conditions
The following table shows the type and extent of tests that were
used to check the product with regard to mechanical ambient
conditions.
Test
Physical quantity
Value, note
Vibrations EN 60068-2-6
(Version 2008)
Vibration
Sine
Frequency range
5 … 500 Hz
Deflection 10 mm
5 … 500 Hz
Vibration acceleration 30 m/s
2
Shock EN 60068-2-27
(Version 2009)
Shock form
Half sine
Peak acceleration
250 m/s
2
Pulse duration
11 ms
Number of shocks
per direction
50 per axis
Number of axes
3