Troubleshooting
78
03.00 | ORG | Assembly and Operating Manual | en | 389246
6 Troubleshooting
6.1 Checking the opening and closing times
If you cannot reach the opening and closing times mentioned in
the latest catalog, please check the following:
Ø
Flow control valves are opened to the maximum extent possible?
(Movement still has to be shock-free!)
Ø
Inner diameter of air hoses is sufficient for the gripper’s air
consumption?
Ø
Air hose between valve and gripper is as short as possible?
Ø
Flow rate of valve is sufficient for the gripper’s air consumption?
If you still cannot achieve the cycle times mentioned in the latest
catalog, we recommend the use of quick-air-vent-valves directly at
the gripper.