Step 5 (Example: Gripper open, approx. 17 mm "OPEN", bracket
rotated 180°)
Ø
Proximity switch S1 is not damped.
Ø
Proximity switch S2 is damped by cam 2 (0.5 mm high).
Proximity switch S2
Proximity switchS1
Step 5 Setting the proximity switches
Ø
The position of the proximity switch S2 on the holding plate (21)
can no longer be adjusted radially outwards. In order to monitor
further "Gripper OPEN" positions, the proximity switch S2 must
now be set in such a way that it is damped by cam 1 (1 mm
high) like proximity switch S1.
Step 6 (Example: Gripper approx. 21 mm "OPEN", bracket
rotated 180°)
Ø
Proximity switch S1 is not damped.
Ø
Proximity switch S2 is damped by cam 1 (1 mm high).