Assembly and initial operation
16
01.03/LPE/en
6
Assembly and initial operation
6.1
Mechanical connection
WARNING
Risk of injury when the machine/system moves
unexpectedly!
Switch off power supply.
Make sure that there is no more residual energy in the
system
WARNING
Risk of injury from falling of the unit during assembly!
Secure unit during assembly with adequately sized straps.
Note the tightening torque of fixing screws.
WARNING
Risk of injury when the machine/system moves
unexpectedly, by moving of the linear axis!
Switch off power supply before assembly and maintenance.
Make sure that there is no more residual energy in the
system
The unit can be mounted by a pillar assembly system Ø 55 or
directly on the horizontal linear axis Beta.
•
Information and dimensional drawings for mounting the pillar
assembly system contains the documentation of the pillar
assembly system in Appendix 2
•
Information for mounting the Linear axis Beta contains the
Service Manual Beta-100-140-ZRS-ZSS, Appendix 1
–
Chapter 6, from page 20.