Maintenance
8.6.3 Mounting orientation of the magnets, item 120
Top view in rotating angle position for 0°-180° variants
Top view in rotating angle position for 0°-90° variants
8.7 Disassembly/assembly of the DKM feed-through compact
module (item 40)
Position of the item numbers,
CAUTION
If the housing (11), bearing ring (82) or bushing (42) are
replaced, a new set of fitting disks (111, 112) must be used.
CAUTION
The balls (142) lie loosely in the ball guide DKM GSM (85).
45