Maintenance
44
07.00 | GSM-P | Assembly and Operating Manual | en | 389104
7.6.3 Mounting orientation of the magnets, item 120
Top view in rotating angle position for 0°-180° variants
Top view in rotating angle position for 0°-90° variants
7.7 Disassembly/assembly of the DKM feed-through compact
module (item 40)
Position of the item numbers
Drawings
[
}
50]
NOTICE
If the housing (11), bearing ring (82), or bushing (44 or 46) is re-
placed, a new set of fitting disks (111 and 112) must be ordered.
NOTICE
The balls (142) lie loosely in the DKM GSM ball guide (85).
Disassembly
Ø
In order to start disassembling the DKM, the steps of disas-
sembly/assembly of the unit must have been carried out in the
basic modules
Disassembly/assembly of the unit in the basic
modules
[
}
40].
Ø
Remove the O-rings (109) and ball guide rail DKM GSM (85)
from the DKM GSM housing.
Ø
Remove the balls (142).
Ø
Turn the screws (140) from the bushing of the gripping module
(31-34) and pull DKM GSM stop 1 (81) and the set of fitting disks
(111/112) off the bushing (44 or 46).