![SCHUNK EGL Assembly And Operating Manual Download Page 56](http://html1.mh-extra.com/html/schunk/egl/egl_assembly-and-operating-manual_1215894056.webp)
Assembly and settings
56
04.00 - FW 2.x | EGL | Assembly and Operating Manual | en | 389661
Ø
Switch on the power supply of the product.
✓
LED 1 and LED 2 light up green.
✓
LED 6 lights up green.
✓
LED 4 lights up red for approx. 5 seconds.
✓
After LED 4 goes out, LED 3 lights up yellow for approx. 5
seconds.
✓
After LED 3 goes out, LED 4 lights up red.
✔
The firmware update was successful and the product is ready
for use.
PROFIBUS communication interface
CAUTION
Risk of damaging the logic board!
If the product is disconnected from the power supply while the
logic board is being updated, the software will not be completely
installed and can no longer be started. The logic board update
cannot be repeated.
•
Do not disconnect the product from the power supply.
•
If the product is disconnected from the power supply while
the logic board is being updated, send the product to SCHUNK
with a repair order.
■
There is new firmware on the USB flash drive
■
The power supply is disconnected from the product
■
DIP switches "1" and "2" are in "OFF" position
Ø
Connect the USB flash drive to the USB Micro AB, host.
Ø
Switch on the power supply of the product.
✓
LED 1 and LED 2 light up green.
✓
LED 6 lights up red.
✓
LED 4 lights up red for approx. 5 seconds.
✓
After LED 4 goes out, LED 3 lights up yellow.
Ø
Switch DIP switch 1 to "ON" position.
✓
LED 1 and LED 2 light up green.
✓
LED 6 lights up red.
✓
LED 3 lights up yellow.
✓
LED 4 flashes red once.