Design and description
03.00 | EGI | Assembly and Operating Manual | en | 1396645
29
LED
Designation
Color
Function
RUN
RUN LED
Red/
Green
LED off:
No supply voltage on and/or EtherCAT device in
'INIT' state.
LED lights up green:
EtherCAT-Device is in 'OPERATIONAL'
state.
LED flashes green:
EtherCAT-Device is in 'PRE-
OPERATIONAL' state.
LED flashes single green:
EtherCAT-Device is in
'OPERATIONAL' state.
LED flickers:
EtherCAT-Device is in 'BOOT' state.
LED lights up red:
If RUN LED (ST) and ERR LED (MS) light
up red, this indicates a serious error. The bus interface
has been put into a physically passive state. Contact
SCHUNK Service.
ERROR ERR LED
Red
LED off:
No supply voltage present and/or no error.
LED flashes red:
Invalid configuration. The status change
requested by the master is not possible due to invalid
register or object settings.
LED flashes single red:
Unrequested status change.
Device has changed the EtherCAT-status independently.
LED flashes double red:
Timeout of the Sync Manager
Watchdog
LED lights up red:
If RUN LED (ST) and ERR LED (MS) light
up red, this indicates a serious error. The bus interface
has been put into a physically passive state. Contact
SCHUNK Service.
LED flickers:
Boot error, e.g. due to a failed firmware
download