5.2.2.4 Magnet status terminal (X1)
The status outputs of the magnet system are connected to the
"Display magnet status" terminal (X1).
Terminal
Description
1 COM
Communication contact, shared connection
2 NO
Normally open contact in the event of demagnetized
system
3 NC
Normally closed contact in the event of
demagnetized system