Assembly and settings
20
01.00 | ECG | Assembly and Operating Manual | en | 389769
5.2.2 ECG-C terminal configuration
5.2.2.1 Jumper operating voltage
NOTE
The operating voltage is preset and may only be changed by SCHUNK.
If the operating voltage is changed retroactively, contact SCHUNK.
5.2.2.2 Terminals in power area (L1, L2, U1, V1)
The voltage supply and the magnetic gripper power is connected
to the following terminals:
Terminal
Description
L1
Input voltage phase 1
L2
Input voltage phase 2
U1
Supply voltage magnetic gripper
V1
Supply voltage magnetic gripper
5.2.2.3 Control terminal (X3)
The signal lines are connected to the "Control" terminal (X3).
Terminal
Description
1 +24 VDC Connection 24 VDC
2 ENABLE Enable contact magnetic gripper actuation
3 MAG
Magnetizing contact (impulse input min. 100 ms)
4 DEMAG Demagnetizing contact (impulse input min. 100 ms)
5 REF
DO NOT ASSIGN! (Service connection)
6 0 V
GND