background image

Translation of Original Operating Manual

Assembly and Operating Manual
APS-ME1

Electronic processor

Summary of Contents for APS-ME1

Page 1: ...Translation of Original Operating Manual Assembly and Operating Manual APS ME1 Electronic processor...

Page 2: ...for the purpose of technical improvement Document number 1415570 Version 01 00 30 09 2019 en SCHUNK Electronic Solutions GmbH All rights reserved Dear Customer thank you for trusting our products and...

Page 3: ...ivery 4 1 3 Warranty 4 2 Basic safety notes 5 2 1 Appropriate use 5 2 2 Inappropriate use 5 2 3 Environmental and operating conditions 5 2 4 Constructional changes 5 2 5 Personnel qualification 6 3 Te...

Page 4: ...instructions in this manual 1 1 1 Applicable documents General terms of business Catalog data sheet of the purchased product Assembly and Operating Manual of the sensors The documents listed here can...

Page 5: ...is not a safety component in accordance with the EC Machine Directive 2006 42 EC and must not be used in safety relevant parts of machine control units 2 3 Environmental and operating conditions Requ...

Page 6: ...g with the product is not sufficiently qualified the result may be serious injuries and significant property damage All work may only be performed by qualified personnel Before working with the produc...

Page 7: ...Designation APS M1E Ambient temperature C Min Max 0 60 Temperature drift C 0 05 Nominal voltage VDC Min Max 24 21 27 Max power consumption W 2 5 Oscillator voltage VSS Sine 7 Oscillator Frequency Hz 4...

Page 8: ...on cable to the terminals of the electronic processor Connection diagram 9 Connect the shield of the sensor cable to the ground terminal Connect the power supply to the evaluation electronics Connect...

Page 9: ...perating Manual en 1415570 9 4 1 1 Connection diagram Connection diagram 1 Connector housing 4 Electronic processor 2 Socket housing 5 Cable extension 3 Automation device 6 Sensor Wire colors bu Blue...

Page 10: ...d and connected Electronic processor is at operating temperature Set the standard signal output 0 10 V or 4 20 mA at the DIP switches Make sure that the unused standard signal output is deactivated Op...

Page 11: ...cessor Gripper overall stroke 0 33 mm Standard signal output 0 10 V Voltage mm 0 303030303 V mm Open the gripper Insert gauge block with 1 mm thickness Close the gripper Set 0 303 V on the 0 point pot...

Page 12: ...12 01 00 APS ME1 Assembly and Operating Manual en 1415570...