Assembly
01.04|AGE-XY 50 - 80|en
11
Air connection
NOTICE
Observe the requirements for the air supply
(
6, Page 9)
.
Fig. 2
air connection
1
connection A "unlock"
2
connection C "save position"
3
connection B "lock"
• Only open the air connections required.
• Seal the air connections not required using with a suitable blind
plug.
7.2