Maintenance
22
02.02|AGE-F-XY 31-80|en
Disassemble the module
Position of the position numbers
(
10, Page 24)
1 Detach the module from the handling device.
2 Disconnect the cable connection.
3 Undo setscrews (51/52) on the bottom of the housing (1).
4 Remove screws (30) on the bottom of the housing (1).
NOTE
When lifting the bottom of the housing (1), the outer guide rails
and the respective roller cages for the linear guide could fall off.
5 Lift the bottom of the housing (1) off the module.
6 Undo setscrews (51/52) on the housing top (2).
7 Remove screws (30) from the housing top (2).
8 Lift the top of the housing (2) off the guide cross (3).
9 Remove screws (5) to separate the linear guide (20) from the
guide cross (3).
WARNING
Risk of injury due to spring forces!
The return springs (15) are installed under bias.
• Diassemble the module carefully.
10 Remove the setscrews (50) from the guide cross (3) in order to
be able to access the return springs (15).
11 Take the guide sleeves (4) out of the guide cross (3).
NOTICE
Loss of precise repeat accuracy
The setscrews (40) are glued in firmly and carefully aligned.
• Do not remove the setscrews.
9.3