Assembly and settings
18
02.02|AGE-F-XY 31-80|en
Programmable magnetic switch (MMS-P)
Programmable magnetic switch MMS-P 22
Connection diagram
NOTICE
Sensor can be damaged during assembly.
• Do not exceed the maximum tightening torque of 10 Ncm for
the setscrews.
NOTE
Ferromagnetic material changes the switching positions of the
sensor. For example: Adapter plate made of ordinary steel.
At ferromagnetic adapter plates:
• The module must firstly be mounted on the adapter plate
• Then, the positions of the magnetic switch have to be set
NOTE
• Do not use the sensor as a safety component.
• Do not pull on the cable of the sensor.
• Secure the cable and connection plug so that they are not
taught and cannot move during operation.
• Do not exceed the permitted bending radius of the cable.
• Do not allow the sensor to come into contact with hard objects
and chemicals (e. g., nitric acid, chromic acid and sulfuric acid).
7.6