BEFORE USING YOUR BATTERY CHARGER

It is important to understand the charger’s requirements. This section explains the
charger’s electrical requirements and how to prepare a battery for charging.

PLUGGING IT IN

Your charger requires a 120V AC
receptacle installed according to all local
codes and ordinances.

USING AN EXTENSION CORD

The use of an extension cord is not
recommended. If you must use an

extension cord, please make sure that
you follow these guidelines:

• Make sure that pins on plug of

extension cord are the same number,
size, and shape as those of plug on
charger.

• Check that the extension cord is

properly wired and in good electrical
condition.

• Make sure that the wire size is large

enough for its length and for the AC
ampere rating, as specified in the
chart below.

Length of Cord, in Feet

25

50

100

150

AWG* Size of Cord

18

16

12

10

*AWG=American Wire Gauge

MINIMUM RECOMMENDED EXTENSION CORD

PREPARING YOUR BATTERY TO BE CHARGED

It is important that you read and follow these guidelines while you are preparing to
charge the battery.

• Make sure that you have a 12 volt

lead-acid battery. Determine voltage
of battery by referring to vehicle
owner’s manual. Charge battery
initially at charger’s lowest rate.

• Clean the battery terminals. Be

careful to keep corrosion from getting
in or around your eyes.

• Wear safety glasses. See additional

“Personal Safety Precautions” on
page 4.

• For batteries with removable vent

caps, if required, add distilled water to
each cell until the battery acid
reaches the level recommended by
the manufacturer. This will help purge
excessive gases from the cells. Be
careful not to overfill. If you have a
sealed battery with non-removable
vent caps, no action is necessary.

• Take time to read all of the battery

manufacturer’s specific precautions,
such as removing or not removing
vent caps while charging, and
recommended rates of charge.

• Be sure that the area around the

battery is well ventilated while it is
being charged. Gas can be forcefully
blown away by using a piece of
cardboard or other nonmetallic
material as a fan.

• If it is necessary to remove the battery

from the vehicle to charge it, always
remove the grounded terminal from
the battery first. Turn off all vehicle
accessories to avoid sparks from
occurring.

NOTE: 

A marine (boat) battery

installed in a boat must be removed
and charged on shore.

Summary of Contents for SSF-1000A SpeedCharge

Page 1: ...ries OWNER S MANUAL Schumacher Electric Corporation Mount Prospect IL 60056 U S A Send Warranty Product Repairs to Customer Service Returns P O Box 280 1025 E Thompson Hoopeston IL 60942 0280 Question...

Page 2: ...his equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment on and off the user is encouraged to try to correct the interfer ence by...

Page 3: ...u begin charging Never allow battery acid to drip on charger when reading specific gravity or filling battery Never set a battery on top of charger WARNING Handling the cord on this product or cords a...

Page 4: ...resh water and soap nearby for use in case battery acid contacts your eyes skin or clothing If this happens wash immediately with soap and water Then get medical attention Avoid touching your eyes whi...

Page 5: ...ve a 12 volt lead acid battery Determine voltage of battery by referring to vehicle owner s manual Charge battery initially at charger s lowest rate Clean the battery terminals Be careful to keep corr...

Page 6: ...ow LED should light and the charging process should start If the CHECK red LED is on check for correct cable connections 8 To disconnect the charger unplug its power cord before attempting to disconne...

Page 7: ...The charger will be set to the Tester Mode for REGULAR battery type CHARGING BATTERY REMOVED FROM THE VEHICLE 6 Press the appropriate control buttons to select the desired charge rate and battery typ...

Page 8: ...he type of battery to be charged to one of the following three REGULAR This is the type of battery usually used in cars trucks and motorcycles These batteries have vent caps and are often marked low m...

Page 9: ...r with no battery O O 0 Voltage meter activated O 0 0 17 0V 2 Amp charge with battery detected O O xx or xx xV 6 Amp charge with battery detected O O xx or xx xV 10 Amp charge with battery detected O...

Page 10: ...ten minutes after the unit is powered up the unit will remain a tester not a charger indefinitely unless a charge rate is selected TESTING AFTER CHARGING After the unit has been changed from tester to...

Page 11: ...charge If the charger detects a sulfated battery the charger will switch to a special mode of operation designed for such batteries Activation of the special desulfation mode is indicated by blinking...

Page 12: ...ermocouple This device monitors the temperature and allows the charger to turn the fan on and off as needed If the temperature rises above a preset level the charge current will be reduced to allow th...

Page 13: ...e and eventually reduces the charge rate in a con trolled manner After the charging process has started the digital display can be used to determine charging progress by selecting the BATTERY mode The...

Page 14: ...power than again if necessary the charger can deliver in 24 hours Battery may also be faulty The green CHARGED light The battery may be fully If the battery is in a vehicle turns on a few minutes afte...

Page 15: ...15 NOTES...

Page 16: ...nufacturer or its authorized representative The manufacturer makes no warranty other than this limited warranty and expressly excludes any implied warranty including any warranty for consequential dam...

Page 17: ...12 V Attention Lire attentivement les consignes de s curit et d utilisation de ce dispositif et les observer chaque emploi Schumacher Electric Corporation Mount Prospect IL 60056 U S A Faire parvenir...

Page 18: ...DU CHARGEUR DE BATTERIE 12 SE FAMILIARISER AVEC LE CHARGEUR 13 CONSEILS POUR LA CHARGE 13 ENTRETIEN 13 POURCENTAGE ET TEMPS DE CHARGE 14 TABLEAU DE D PANNAGE 15 GARANTIE LIMIT E 16 TABLE DES MATI RES...

Page 19: ...endroit bien a r MISE EN GARDE les chargeurs de batterie d gagent beaucoup de chaleur et il importe de les utiliser dans un endroit bien a r L air doit pouvoir circuler tout autour du chargeur Ne plac...

Page 20: ...ujours le chargeur dans un endroit ouvert et bien a r Ne fumez jamais pr s d une batterie ou d un moteur et ne produisez pas d tincelles proximit Les batteries produisent des gaz explosifs Neutralisez...

Page 21: ...us que la batterie est bien de 12 V et au plomb acide Consultez le guide de conduite et d entretien du v hicule pour conna tre le voltage de la batterie La premi re fois chargez la batterie au taux de...

Page 22: ...r sur une pi ce m tallique paisse et non peinte du ch ssis ou du bloc moteur l cart de la batterie voir l illustration NE BRANCHEZ PAS la pince la borne n gative de la batterie au carburateur la canal...

Page 23: ...e N GATIF au bout libre du c ble 5 Branchez le cordon d alimentation dans une prise CA Le chargeur sera r gl par d faut au mode testeur pour une batterie de type ORDINAIRE 6 Appuyez sur les boutons ap...

Page 24: ...d charge pouss e sont g n ralement de plus grande taille que les autres batteries SPFV LECTROLYTE G LIFI Les batteries s parateurs poreux en fibre de verre SPFV et lectrolyte g lifi sont des batterie...

Page 25: ...batterie A A 0 Voltm tre activ A 0 0 17 0V Charge de 2 A avec batterie d tect e A A xx or xx xV Charge de 6 A avec batterie d tect e A A xx or xx xV Charge de 10 A avec batterie d tect e A A xx or xx...

Page 26: ...rie soit branch e au chargeur Dans ce cas le chargeur reviendra aux valeurs par d faut de 2 Apour une batterie ordinaire TESTEUR SANS LIMITE DE TEMPS Si vous appuyez sur le bouton Mode d affichage ou...

Page 27: ...juste il suffit d liminer la charge de surface en cr ant une demande temporaire sur la batterie du v hicule comme allumer les phares ou d autres accessoires Le pourcentage est mesur de 0 100 Le teste...

Page 28: ...venir sulfur e et ne plus accepter de charge Si le chargeur d tecte que la batterie est sulfur e il passera automatiquement un mode sp cial con u pour ce type de situ ation L activation du cycle de d...

Page 29: ...nement optimal du chargeur vitez de le placer en plein soleil ou dans un endroit confin o la temp rature est lev e CONSEILS POUR LA CHARGE Ranimer la batterie Si vous d sirez re charger la batterie ju...

Page 30: ...e plus grande taille Le chargeur fournit au d but du cycle de charge le taux s lectionn puis r duit automatiquement le taux de fa on contr l e Une fois que le cycle de charge a t enclench on peut r gl...

Page 31: ...rebranchant ou en compl tement charg e heures La batterie peut d branchant bri vement tre d une tr s grande la pince fix e au p le capacit ou tre n gatif de la batterie compos e de plusieurs S lection...

Page 32: ...is postaux pr pay s au fabricant ou l un de ses repr sentants agr s Cette garantie est nulle si le produit est l objet d un usage impropre s il est manipul avec n gligence ou s il est r par ailleurs q...

Reviews: